Image-based robotic (ROSA® knee system) total knee arthroplasty with inverse kinematic alignment compared to conventional total knee arthroplasty
Authors:
Open Access
- 15 January 2025
- journal article
- research article
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 20 (1) , 1-11
Abstract
In 2020, 368 million people globally were affected by knee osteoarthritis, and prevalence is projected to increase with 74% by 2050. Relatively high rates of dissatisfactory results after total knee arthroplasty (TKA), as reported by approximately 20% of patients, may be caused by sub-optimal knee alignment and balancing. While mechanical alignment has traditionally been the goal, patient-specific alignment strategies are gaining interest. Robotic assistance could potentially facilitate implementation of these alignment strategies through data-based surgical planning, accurate execution of the surgical plan and validation. The clinical value of surgical assistance in diverging from mechanical alignment remains to be investigated. In the present study, robotic-assisted TKA will be performed to pursue inverse kinematic alignment (iKA) within predefined boundaries, focusing on restoring native tibia joint line. This randomized controlled trial evaluates clinical effectiveness of robotic-assisted TKA (ROSA® Knee System, Zimmer Biomet, Montreal, Quebec, Canada) aiming for iKA compared to conventional TKA aiming for mechanical alignment. A total of 150 participants will be randomized (1:1) to either treatment to provide an 80% power for a 4.8-point clinically important difference in the primary outcome measure, the Oxford Knee Score (OKS) 12 months after surgery. Allocation was achieved using computer-based randomization. Outcomes will be analyzed using linear mixed models with time and group as main factors and interaction-term. Secondary outcomes include clinical metrics (leg alignment, implant and patient survival), surgical parameters (adverse events, surgery duration, blood loss, hospital stay length, medication use), patient-reported outcomes (symptoms, quality of life, pain), mobility and physical activity measurements, metabolic syndrome, cost-efficacy, and gait and continuous glucose monitoring. This study has been approved by the Medical Ethical Committee Zuyd and Zuyderland Medical Centre (NL79161.096.21/METCZ20220006), September 2022. NCT05685693 (clinicaltrials.gov).Keywords
This publication has 51 references indexed in Scilit:
- Glucotypes reveal new patterns of glucose dysregulationPLOS Biology, 2018
- Patient Satisfaction after Total Knee Replacement: A Systematic ReviewHSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery, 2018
- CONCEPTUALIZATIONS OF THE SOCIETAL PERSPECTIVE WITHIN ECONOMIC EVALUATIONS: A SYSTEMATIC REVIEWInternational Journal of Technology Assessment in Health Care, 2017
- Presence of rotational errors in long leg radiographs after total knee arthroplasty and impact on measured lower limb and component alignmentInternational Orthopaedics, 2017
- Bioimpedance at the BedsideNutrition in Clinical Practice, 2015
- Meaningful changes for the Oxford hip and knee scores after joint replacement surgeryJournal of Clinical Epidemiology, 2015
- Do patient-reported outcome measures in hip and knee arthroplasty rehabilitation have robust measurement attributes? A systematic reviewJournal of Rehabilitation Medicine, 2011
- Diagnosis and Management of the Metabolic SyndromeCirculation, 2005
- Translation and validation of the Dutch version of the Oxford 12-item knee questionnaire for knee arthroplastyActa Orthopaedica, 2005
- Satisfactory cross cultural equivalence of the Dutch WOMAC in patients with hip osteoarthritis waiting for arthroplastyAnnals of the Rheumatic Diseases, 2004