Blood self-sampling devices: innovation, interpretation and implementation in total lab automation
Open Access
- 19 June 2024
- journal article
- review article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 63 (1) , 3-13
Abstract
The introduction of the vacuum tube in 1949 revolutionized blood collection, significantly improving sample quality and patient comfort. Over the past 75 years, laboratory diagnostics have evolved drastically, from manual to automated processes, reducing required test volumes by over 1,000 times. Despite these advancements, venous blood collection presents logistical challenges, including centralized scheduling and a large volume of biological waste due to the imbalance between the needed blood volume (often very little) and the collected volume (often in excess). The COVID-19 pandemic further emphasized the need for decentralized healthcare solutions and patient empowerment. Capillary blood collection, widely used in point-of-care testing, offers a promising alternative, particularly for patients facing frequently, or difficulties with, venous sampling. The Leiden University Medical Center in the Netherlands experienced a 15 % reduction in volume of laboratory tests during and after the pandemic, attributed to patient preference for local blood collection and testing. To address these challenges, self-sampling devices are emerging, empowering patients and streamlining sample logistics. However, challenges such as cost, transportation regulations, and sample volume adequacy persists. Robust devices tailored for total lab automation and sustainable practices are crucial for widespread adoption. Despite hurdles, the integration of self-sampling into diagnostic processes is inevitable, heralding a shift towards patient-centered, proactive healthcare. Practical recommendations include robust device design, ease of use, affordability, sustainability, sufficient quality and acceptability by seamless integration into laboratory workflows. Although obstacles remain, self-sampling represents the future of laboratory diagnostics, offering convenience, cost-effectiveness, interoperability and patient empowerment.Keywords
This publication has 46 references indexed in Scilit:
- Effect of using smaller blood volume tubes and closed blood collection devices on total blood loss in patients undergoing major cardiac and vascular surgeryCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2024
- Dried Blood Spots—A Platform for Therapeutic Drug Monitoring (TDM) and Drug/Disease Response Monitoring (DRM)European Journal of Drug Metabolism and Pharmacokinetics, 2023
- Clinical validation of novel dried blood spot based collecting device using serum separation for measuring SARS‐CoV‐2 antibodiesJournal of Medical Virology, 2023
- Determination of lithium concentration in capillary blood using volumetric dried blood spotsJournal of Pharmaceutical and Biomedical Analysis, 2023
- Automated and combined HIV, HBV, HCV, and syphilis testing among illegal gold miners in French Guiana using a standardized dried blood deviceActa Tropica, 2022
- Classification of HIV-1 virological treatment failure using the Roche cobas plasma separation card on cobas 8800 compared to dried blood spots on Abbott RealTime HIV-1Journal of Clinical Virology, 2021
- Initial validation of a virtual blood draw exposure paradigm for fear of blood and needlesJournal of Anxiety Disorders, 2017
- Hospital‐acquired anemia: Prevalence, outcomes, and healthcare implicationsJournal of Hospital Medicine, 2013
- Automated method for the direct determination of total serum cholesterolClinica Chimica Acta, 1964
- LICHEN PLANUS IN THE NEGROArchives of Dermatology, 1947