Localised photoplethysmography imaging for heart rate estimation of pre-term infants in the clinic
- 20 February 2018
- conference paper
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10501, 26
Abstract
Non-contact vital-sign estimation allows the monitoring of physiological parameters (such as heart rate, respiratory rate, and peripheral oxygen saturation) without contact electrodes or sensors. Our recent work has demonstrated that a convolutional neural network (CNN) can be used to detect the presence of a patient and segment the patient’s skin area for vital-sign estimation, thus enabling the automatic continuous monitoring of vital signs in a hospital environment. In a study approved by the local Research Ethical Committee, we made video recordings of pre-term infants nursed in a Neonatal Intensive Care Unit (NICU) at the John Radcliffe Hospital in Oxford, UK. We extended the CNN model to detect the head, torso and diaper of the infants. We extracted multiple photoplethysmographic imaging (PPGi) signals from each body part, analysed their signal quality, and compared them with the PPGi signal derived from the entire skin area. Our results demonstrated the benefits of estimating heart rate combined from multiple regions of interest using data fusion. In the test dataset, we achieved a mean absolute error of 2.4 beats per minute for 80% (31.1 hours) from a total recording time of 38.5 hours for which both reference heart rate and video data were valid.Keywords
This publication has 10 references indexed in Scilit:
- Faster R-CNN: Towards Real-Time Object Detection with Region Proposal NetworksIEEE Transactions on Pattern Analysis and Machine Intelligence, 2016
- Overcoming the practical challenges of electroencephalography for very preterm infants in the neonatal intensive care unitActa Paediatrica, 2015
- Continuous non‐contact vital sign monitoring in neonatal intensive care unitHealthcare Technology Letters, 2014
- Non-contact video-based vital sign monitoring using ambient light and auto-regressive modelsPhysiological Measurement, 2014
- Non-contact heart rate monitoring utilizing camera photoplethysmography in the neonatal intensive care unit — A pilot studyEarly Human Development, 2013
- Dynamic time warping and machine learning for signal quality assessment of pulsatile signalsPhysiological Measurement, 2012
- Remote plethysmographic imaging using ambient lightOptics Express, 2008
- Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filterPhysiological Measurement, 2007
- Vital signs in hospital patients: a systematic reviewInternational Journal of Nursing Studies, 2001
- Numerical Bayesian Methods Applied to Signal Processing1996