Optimal threshold of a control parameter for tomotherapy respiratory tracking: A phantom study
Open Access
- 12 January 2023
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (5)
Abstract
Background: Radixact Synchrony®, a real‐time motion tracking and compensating modality, is used for helical tomotherapy. Control parameters are used for the accurate application of irradiation. Radixact Synchrony® uses the potential difference, which is an index of the accuracy of the prediction model of target motion and is represented by a statistical prediction of the 3D distance error. Although there are several reports on Radixact Synchrony®, few have reported the appropriate settings of the potential difference threshold.Purpose: This study aims to determine the optimal threshold of the potential difference of Radixact Synchrony® during respiratory tumor‐motion‐tracking irradiation.Methods: The relationship among the dosimetric accuracy, motion tracking accuracy, and control parameter was evaluated using a moving platform, a phantom with a basic respiratory model (the fourth power of a sinusoidal wave), and several irregular respiratory model waveforms. The dosimetric accuracy was evaluated by gamma analysis (3%, 1 mm, 10% dose threshold). The tracking accuracy was measured by the distance error of the difference between the tracked and driven positions of the phantom. The largest potential difference for 95% of treatment time was evaluated, and its correlation with the gamma‐pass ratio and distance error was investigated. The optimal threshold of the potential difference was determined by receiver operating characteristic (ROC) analysis.Results: A linear correlation was identified between the potential difference and the gamma‐pass ratio (R = –0.704). A linear correlation was also identified between the potential difference and distance error (R = 0.827). However, as the potential difference increased, it tended to underestimate the distance error. The ROC analysis revealed that the appropriate cutoff value of the potential difference was 3.05 mm.Conclusion: The irradiation accuracy with motion tracking by Radixact Synchrony® could be predicted from the potential difference, and the threshold of the potential difference should be set to ∼3 mm.Keywords
This publication has 18 references indexed in Scilit:
- Feasibility of real‐time motion management with helical tomotherapyMedical Physics, 2018
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Intrafractional Baseline Shift or Drift of Lung Tumor Motion During Gated Radiation Therapy With a Real-Time Tumor-Tracking SystemInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2016
- Evaluation of respiratory pattern during respiratory-gated radiotherapyAustralasian Physics & Engineering Sciences in Medicine, 2014
- Incidence of Changes in Respiration-Induced Tumor Motion and Its Relationship With Respiratory Surrogates During Individual Treatment FractionsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Motion-induced dose artifacts in helical tomotherapyPhysics in Medicine & Biology, 2009
- Correlation between internal fiducial tumor motion and external marker motion for liver tumors imaged with 4D-CTInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)Medical Physics, 2006
- Measurement of the interplay effect in lung IMRT treatment using EDR2 filmsJournal of Applied Clinical Medical Physics, 2006
- Tomotherapy: A new concept for the delivery of dynamic conformal radiotherapyMedical Physics, 1993