Accuracy and reproducibility of co-registration techniques based on mutual information and normalized mutual information for MRI and SPECT brain images
Authors:
- 1 December 2004
- journal article
- research article
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 18 (8) , 659-667
Abstract
We implemented a 3D co-registration technique based on mutual information (MI) including 2D image matching as a coarse pre-registration. The 2D coarse pre-registration was performed in the transverse, sagittal and coronal planes sequentially, and all six parameters were then optimized as fine registration. Normalized mutual information (NMI) was also examined as another entropybased measure that was invariant to the overlapped area of two images. In order to compare accuracy and precision of the present method with a conventional two-level multiresolution approach, simulation was performed by 100 trials with the random initial mismatch of ±10° and ±17.92 mm (Type-I) and ±20° and ±40.32 mm (Type-II). For Type-I, no significant differences were found between registration errors of the multiresolution approach and the present method with the MI criterion. No biases were observed (≤0.13° and ≤0.57 mm for the multiresolution approach; ≤0.12° and ≤0.57 mm for the present method) and the SDs were very small (≤0.18° and ≤0.12 mm for the multiresolution approach; ≤0.11° and ≤0.11 mm for the present method). For Type-II, SDs for the multiresolution approach (≤1.8° and ≤0.88 mm) were markedly larger than those for the present method (≤0.64° and ≤0.20 mm) with MI. Success rate for the present method was 99.9%, which was higher than 97.6% for the multiresolution approach. Simulation also revealed that MI and NMI performance were almost equivalent. The choice of optimization strategy more affected accuracy and reproducibility than the choice of the registration criterion (MI or NMI) in our simulation condition. The present method is sufficiently accurate and reproducible for MRI-SPECT registration in clinical use.Keywords
This publication has 32 references indexed in Scilit:
- Magnetic resonance imaging-guided attenuation and scatter corrections in three-dimensional brain positron emission tomographyMedical Physics, 2003
- SPET/CT image co-registration in the abdomen with a simple and cost-effective toolEuropean Journal of Nuclear Medicine and Molecular Imaging, 2003
- Attenuation correction of myocardial SPECT images with X-ray CT: Effects of registration errors between X-ray CT and SPECTAnnals of Nuclear Medicine, 2002
- Technical and analytical advances in pulmonary ventilation SPECT with xenon-133 gas and Tc-99m-TechnegasAnnals of Nuclear Medicine, 2002
- Validation of fully automatic brain SPET to MR co-registrationEuropean Journal of Nuclear Medicine and Molecular Imaging, 2000
- Comparison and Evaluation of Retrospective Intermodality Brain Image Registration TechniquesJournal of Computer Assisted Tomography, 1997
- Abdominal SPECT/MRI fusion applied to the study of splenic and hepatic uptake of radiolabeled thrombocytes and colloidsAnnals of Nuclear Medicine, 1996
- A Fully Automatic Multimodality Image Registration AlgorithmJournal of Computer Assisted Tomography, 1995
- Quantitative Comparisons of Image Registration Techniques Based on High-Resolution MRI of the BrainJournal of Computer Assisted Tomography, 1994
- MRI-PET Registration with Automated AlgorithmJournal of Computer Assisted Tomography, 1993