SeisMote: A Multi-Sensor Wireless Platform for Cardiovascular Monitoring in Laboratory, Daily Life, and Telemedicine
Open Access
Abstract
This article presents a new wearable platform, SeisMote, for the monitoring of cardiovascular function in controlled conditions and daily life. It consists of a wireless network of sensorized nodes providing simultaneous multiple measures of electrocardiogram (ECG), acceleration, rotational velocity, and photoplethysmogram (PPG) from different body areas. A custom low-power transmission protocol was developed to allow the concomitant real-time monitoring of 32 signals (16 bit @200 Hz) from up to 12 nodes with a jitter in the among-node time synchronization lower than 0.2 ms. The BluetoothLE protocol may be used when only a single node is needed. Data can also be collected in the off-line mode. Seismocardiogram and pulse transit times can be derived from the collected data to obtain additional information on cardiac mechanics and vascular characteristics. The employment of the system in the field showed recordings without data gaps caused by transmission errors, and the duration of each battery charge exceeded 16 h. The system is currently used to investigate strategies of hemodynamic regulation in different vascular districts (through a multisite assessment of ECG and PPG) and to study the propagation of precordial vibrations along the thorax. The single-node version is presently exploited to monitor cardiac patients during telerehabilitation.Keywords
This publication has 30 references indexed in Scilit:
- Wearable seismocardiography: Towards a beat-by-beat assessment of cardiac mechanics in ambulant subjectsAutonomic Neuroscience, 2013
- Simplified detection of myocardial ischemia by seismocardiographyHerz, 2013
- Photoplethysmography and its application in clinical physiological measurementPhysiological Measurement, 2007
- The History, Science, and Innovation of Holter TechnologyAnnals of Noninvasive Electrocardiology, 2006
- Heart Rate Variability in Patients with Essential Hyperhidrosis: Dynamic Influence of Sympathetic and Parasympathetic ManeuversAnnals of Noninvasive Electrocardiology, 2005
- Real-time communications using TDMA-based multi-access protocolComputer Communications, 1997
- Energy absorption mechanism by biological bodies in the near field of dipole antennas above 300 MHzIEEE Transactions on Vehicular Technology, 1992
- Determination of pulse wave velocities with computerized algorithmsAmerican Heart Journal, 1991
- Access-control disciplines for multi-access communication channels: Reservation and TDMA schemesIEEE Transactions on Information Theory, 1979
- Adaptive Quantization in Differential PCM Coding of SpeechBell System Technical Journal, 1973