Comparison of method-related reference intervals for thyroid hormones: studies from a prospective reference population and a literature review
Authors:
Open Access
- 8 May 2017
- journal article
- research article
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 55 (1) , 107-112
Abstract
Introduction: Reference intervals are dependent on the reference population, the analytical methods and the way the data are handled statistically. Individual method-related differences have been studied but the comparative differences in reference intervals have not. Methods: We studied a reference population of healthy adult subjects and measured free thyroxine and thyroid-stimulating hormone by the four most commonly used analytical platforms used in the UK. Subjects were excluded if they were > 65 years or had positive thyroid peroxidase antibodies. We also performed a systematic literature review of thyroid hormone reference interval studies in non-pregnant adults. Results: In total, 303 subjects were recruited and 42 excluded. The central 95th centile values for thyroid-stimulating hormone (mIU/L) were Abbott Architect (0.51–3.67); Beckman Unicel DxI (0.57–3.60); Roche Cobas (0.60–4.31) and Siemens Advia Centaur XP (0.63–4.29). The 95th centile values for thyroxine (pmol/L) were Abbott Architect (10.6–15.5); Beckman Unicel DxI (7.9–13.0); Roche Cobas (12.5–19.6) and Siemens Advia Centaur XP (11.8–19.0). We identified 55 papers describing thyroid reference intervals in male and non-pregnant female adults. The values for upper and lower reference intervals by manufacturer varied but were not significantly different for thyroid-stimulating hormone but were for thyroxine. Discussion: Our study demonstrates clearly that there are marked variations in the reference intervals for thyroid hormones between analytical platforms. There is an urgent need for standardization of thyroid hormone assays to permit transferability of results. Until then, guidelines will need to reflect this method-related difference.Keywords
This publication has 9 references indexed in Scilit:
- Reference intervals for thyroid hormones on Advia Centaur derived from three reference populations and a review of the literatureAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2016
- The upper reference limit for thyroid peroxidase autoantibodies is method-dependent: A collaborative study with biomedical industriesClinica Chimica Acta, 2016
- Normal limits for serum thyrotropin vary greatly depending on methodClinical Endocrinology, 2015
- Protocol and standard operating procedures for common use in a worldwide multicenter study on reference valuesClinical Chemistry and Laboratory Medicine (CCLM), 2013
- Pathology Harmony; a pragmatic and scientific approach to unfounded variation in the clinical laboratoryAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2011
- Report of the IFCC Working Group for Standardization of Thyroid Function Tests; Part 1: Thyroid-Stimulating HormoneClinical Chemistry, 2010
- Report of the IFCC Working Group for Standardization of Thyroid Function Tests; Part 2: Free Thyroxine and Free TriiodothyronineClinical Chemistry, 2010
- Report of the IFCC Working Group for Standardization of Thyroid Function Tests; Part 3: Total Thyroxine and Total TriiodothyronineClinical Chemistry, 2010
- Knowing the Serum C-Reactive Protein Concentration is not Helpful When Interpreting Thyroid Function TestsAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1999