Development of an Objective Portable Measurement Device for Spinal Joint Accessory Motion Testing
Open Access
Abstract
Joint accessory motion testing (JAMT) is a standard procedure used by manual therapists to assess and treat musculoskeletal disorders. Joint accessory motion (JAM) is movement that occurs between joint surfaces, and can be induced by applying force. The motion amount, end feel, symptoms, and resistance perceived by therapists during test procedures are recorded as evidence for the diagnosis, prognosis, treatment decision making, and intervention outcome. However, previous studies have shown that accessory motion tests have insufficient reliability. Recently, many instruments have been developed to increase test reliability, but these instruments quantify the test results with a single probe and utilize the external environment as a reference. Therefore, the measured displacement amount may be affected by other spinal segments. This study proposes an objective portable measurement device with two indenter probes for spinal JAMT, wherein the JAM was quantified by displacement and force measurements between two bones. The instrument was verified with a homemade spinal simulator and computer simulation. The results showed that the force-displacement curves measured by the JAMT device (JAMTD) and those simulated by the computer model exhibited similar characteristics. Moreover, a two-probe measurement could distinguish the differences in stiffness better than a one-probe measurement.Keywords
Funding Information
- Ministry of Science and Technology, Taiwan (99-2221-E-010-003-MY2)
This publication has 33 references indexed in Scilit:
- Within- and between-day reliability of spinal stiffness measurements obtained using a computer controlled mechanical indenter in individuals with and without low back painManual Therapy, 2013
- Spinal stiffness in asymptomatic subjectsJournal of Electromyography and Kinesiology, 2011
- Performance and Reliability of a Variable Rate, Force/Displacement Application SystemJournal of Manipulative and Physiological Therapeutics, 2010
- Reliability of assisted indentation in measuring lumbar spinal stiffnessManual Therapy, 2009
- Measuring the posteroanterior stiffness of the cervical spineManual Therapy, 2008
- Relation Between Changes in Posteroanterior Stiffness and Active Range of Movement of the Cervical Spine Following Manual Therapy TreatmentSpine, 2008
- Morphological and Functional Electrophysiological Evidence of Relative Spinal Cord Tethering in Adolescent Idiopathic ScoliosisSpine, 2008
- Reliability of Spinal Palpation for Diagnosis of Back and Neck PainSpine, 2004
- Effect of position on the posteroanterior stiffness of the lumbar spineManual Therapy, 1998
- Ratio scales of sensory and affective verbal pain descriptorsPain, 1978