Analysis of Silicon Dioxide and Silicon Nitride Powders by Electrothermal Vaporization Inductively Coupled Plasma Atomic Emission Spectrometry Using a Tungsten Coil and Slurry Sampling
Authors:
- Peter BarthPBPeter Barth
- Susanne HauptkornSHSusanne Hauptkorn
- Viliam KrivanVKViliam Krivan
- 1 January 1997
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 12 (12) , 1359-1365
Abstract
Slurry sampling in combination with ETV-ICP-AES was employed for the direct determination of trace amounts of impurities in silicon dioxide and silicon nitride. The ETV device consisted of a double layer tungsten coil in a quartz apparatus. Spectral interferences and background emission caused by tungsten ablation of the coil were reduced by coating the coil with tungsten carbide. The background was measured either with a high-purity sample, the suspension medium or close to the analyte emission line, depending on matrix and analyte, or it was calculated using relative emission intensities of tungsten. The concentrations of Al, B, Be, Ca, Cd, Co, Cr, Cu, Fe, Mg, Mn, Ni, Pb and Zn were measured simultaneously, whereas K and Na were determined in the sequential mode. Calibration was performed using the standard additions method. The accuracy was checked by comparison with the results of independent methods. Limits of detection between 0.035 (Mg) and 130 µg g–1 (B) and between 0.01 (Be, Mg) and 34 µg g–1 (B) were achieved in silicon dioxide and silicon nitride, respectively.Keywords
This publication has 49 references indexed in Scilit:
- Determination of metallo-organic species in lubricating oil by electrothermal vaporization inductively coupled plasma mass spectrometryAnalytica Chimica Acta, 1996
- Fluorination with polytetrafluoroethylene slurry in electrothermal vaporization-inductively coupled plasma-atomic emission spectrometryAnalytica Chimica Acta, 1996
- Analytical evaluation of a tungsten coil atomizer for cadmium, lead, chromium, manganese, nickel and cobalt determination by electrothermal atomic absorption spectrometryAnalytica Chimica Acta, 1995
- Communication. Assessment of direct solid sample analysis by graphite pellet electrothermal vaporization inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1995
- Graphite furnace hydride preconcentration and subsequent detection by inductively coupled plasma mass spectrometryAnalytica Chimica Acta, 1994
- Determination of trace impurities in organometallic semiconductor-grade reagents and process chemicals with electrothermal vaporization–inductively coupled plasma atomic emission spectrometryJournal of Analytical Atomic Spectrometry, 1994
- Direct solids analysis of geological samples using slurry nebulization inductively coupled plasma atomic emission spectrometryJournal of Analytical Atomic Spectrometry, 1993
- Determination of cadmium in biological materials by tungsten coil atomic absorption spectrometryJournal of Analytical Atomic Spectrometry, 1993
- Determination of boron in high-purity silica using direct current plasma emission spectrometryAnalytica Chimica Acta, 1991
- INVESTIGATION OF DIRECT SAMPLE INSERTION AND TUNGSTEN FILAMENT ELECTROTHERMAL VAPORIZATION FOR MICRO SAMPLE ANALYSIS BY ICP-AESAnalytical Sciences, 1991