Medial femoral head border is a reliable and reproducible reference for axis determination for femoral component of unicompartmental knee arthroplasty
- 28 September 2012
- journal article
- knee
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 21 (11) , 2442-2446
Abstract
Purpose: The femoral component should be implanted parallel to the mechanical axis in unicompartmental knee arthroplasty. It was hypothesised that a line between medial femoral condyle centres and medial border of femoral head will be parallel to the mechanical axis; this study set out to examine this hypothesis.Methods: One hundred X‐rays in fifty patients were included for this study. Long‐leg standing X‐rays including hip and ankle with patellae facing forwards were obtained. On these films, we measured the angle, α, between mechanical axis and the line between the femoral head centre and knee centre (medial mechanical axis), and the angle, β, between the medial mechanical axis and a line between medial femoral condyle and femoral head centre.Results: The average value of α was 0.1 ± 0.5° and the average value of β 3.0° ± 0.3°. These data indicate that mechanical axis and medial mechanical axis are virtually parallel to each other.Conclusion: As medial femoral head border is easily identified fluoroscopically, it is a reliable landmark for orientating the femoral component of medial UKA.Level of evidence: Case series with no comparison group, Level IV.Keywords
This publication has 18 references indexed in Scilit:
- The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 yearsThe Journal of Bone and Joint Surgery. British volume, 2011
- The incidence of physiological radiolucency following Oxford unicompartmental knee replacement and its relationship to outcomeThe Journal of Bone and Joint Surgery. British volume, 2009
- Does Accurate Anatomical Alignment Result in Better Function and Quality of Life? Comparing Conventional and Computer-Assisted Total Knee ArthroplastyThe Journal of Arthroplasty, 2009
- Influence of component alignment on outcome for unicompartmental knee replacementThe Knee, 2009
- Computer Navigation-assisted versus Minimally Invasive TKAClinical Orthopaedics and Related Research, 2008
- Alignment in total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2008
- Alignment of the femoral component in a mobile-bearing unicompartmental knee arthroplasty: A study in 10 cadaver femoraThe Knee, 2007
- Unicompartmental versus computer-assisted total knee replacement for medial compartment knee arthritis: a matched paired studyInternational Orthopaedics, 2006
- Medial Unicornpartmental ArthroplastyClinical Orthopaedics and Related Research, 1993
- Unicompartmental Arthroplasty of the KneeClinical Orthopaedics and Related Research, 1987