Simultaneous monitoring of amoxicillin and paracetamol in synthetic biological fluids using a 3D printed disposable electrode with a lab-made conductive filament
- 4 November 2023
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 416 (1) , 215-226
Abstract
In this work, we are pleased to present for the first time a 3D-printed electrochemical device using a lab-made conductive filament based on graphite (Gr) and polylactic acid (PLA) polymer matrix for the simultaneous detection of amoxicillin (AMX) and paracetamol (PAR). The sensor was properly characterized by scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). Compared to the commercial glassy carbon electrode (GCE), the superior performance of the 3D-Gr/PLA electrode was verified with a 3.8-fold more favored charge transfer. A differential pulse voltammetry (DPV) method was proposed providing a linear working range of 4 to 12 μmol L-1 for both analytes and a limit of detection (LOD) of 0.80 and 0.51 μmol L-1 for AMX and PAR, respectively. Additionally, repeatability studies (n = 5, RSD < 5.7%) indicated excellent precision, and recovery percentages ranging from 89 to 109% when applied to synthetic human urine, saliva, and plasma samples, attested to the accuracy of the method. The studies also indicate that the sensor does not suffer significant interference from common substances (antibiotics and biomarkers) present in the biological fluids, which makes it a promising analytical tool considering its low-cost, ease of manufacturing, robustness, and electrochemical performance. Graphical abstractKeywords
Funding Information
- Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro (E-33/201.429/2022)
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (001)
- Conselho Nacional de Desenvolvimento Científico e Tecnológico (303815/2022-1)
This publication has 67 references indexed in Scilit:
- A novel voltammetric sensor for amoxicillin based on nickel–curcumin complex modified carbon paste electrodeBioelectrochemistry, 2012
- Simultaneous determination of amoxicillin and ambroxol in human plasma by LC–MS/MS: Validation and application to pharmacokinetic studyJournal of Pharmaceutical and Biomedical Analysis, 2008
- The clinical development and launch of amoxicillin/clavulanate for the treatment of a range of community-acquired infectionsInternational Journal of Antimicrobial Agents, 2007
- Different strategies for the direct determination of amoxicillin in human urine by second-order multivariate analysis of kinetic–spectrophotometric dataTalanta, 2007
- Raman spectroscopy of graphitePhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2004
- The quantification of paracetamol, paracetamol glucuronide and paracetamol sulphate in plasma and urine using a single high-performance liquid chromatography assayJournal of Pharmaceutical and Biomedical Analysis, 2004
- Laser-probe-based investigation of the evolution of particle size distributions of calcium oxalate particles formed in artificial urinesJournal of Crystal Growth, 2001
- A statistical overview of standard (IUPAC and ACS) and new procedures for determining the limits of detection and quantification: Application to voltammetric and stripping techniques (Technical Report)Pure and Applied Chemistry, 1997
- Bioactive glass ceramics: properties and applicationsBiomaterials, 1991
- Amoxicillin: In Vitro and Pharmacological StudiesAntimicrobial Agents and Chemotherapy, 1972