Portable nuclear magnetic resonance biosensor and assay for a highly sensitive and rapid detection of foodborne bacteria in complex matrices
Open Access
- 27 March 2017
- journal article
- research article
- Published by Springer Nature in Journal of Biological Engineering
- Vol. 11 (1) , 1-8
Abstract
Nuclear magnetic resonance (NMR) technique is a powerful analytical tool in determining the presence of bacterial contaminants in complex biological samples. In this paper, a portable NMR-based (pNMR) biosensor and assay to detect the foodborne bacteria Escherichia coli O157:H7 is reported. It uses antibody-functionalized polymer-coated magnetic nanoparticles as proximity biomarker of the bacteria which accelerates NMR resonance signal decay. The pNMR biosensor operates at 0.47 Tesla of magnetic strength and consists of a high-power pulsed RF transmitter and an ultra-low noise sensing circuitry capable of detecting weak NMR signal at 0.1 μV. The pNMR biosensor assay and sensing mechanism is used in detecting E. coli O157:H7 bacteria in drinking water and milk samples. Experimental results demonstrate that by adding a filtration step in the assay, the pNMR biosensor is able to detect E. coli O157:H7 as low as 76 CFU/mL in water samples and as low as 92 CFU/mL in milk samples in about one min. The pNMR biosensor assay and sensing system is innovative for foodborne bacterial detection in food matrices. The lowest detection level for E. coli O157:H7 in water and milk samples is essentially 101 CFU/mL. Although the linear range of detection is only from 101 to 104 CFU/mL, the wider detection range spans from 101 CFU/mL to 107 CFU/mL. Existing pNMR biosensors have detection limits at 103-104 CFU/mL only. The detection technique can be extended to other microbial or viral organisms by merely changing the specificity of the antibodies. Besides food safety, the pNMR biosensor described in this paper has potential to be applied as a rapid detection device in biodefense and healthcare diagnostic applications.Keywords
Funding Information
- 21st Century Jobs Fund
This publication has 19 references indexed in Scilit:
- Sensitive Chemiluminescence Immunoassay for E. coli O157:H7 Detection with Signal Dual-Amplification Using Glucose Oxidase and LaccaseAnalytical Chemistry, 2014
- Development of a Multiplex PCR Assay for Detection of Shiga Toxin-Producing Escherichia coli, Enterohemorrhagic E. coli, and Enteropathogenic E. coli StrainsFrontiers in Cellular and Infection Microbiology, 2012
- Economic Burden from Health Losses Due to Foodborne Illness in the United StatesJournal of Food Protection, 2012
- Rapid detection and profiling of cancer cells in fine-needle aspiratesProceedings of the National Academy of Sciences, 2009
- Toward portable nuclear magnetic resonance devices using atomic magnetometersConcepts in Magnetic Resonance Part A, 2009
- Chip–NMR biosensor for detection and molecular analysis of cellsNature Medicine, 2008
- Electrically Active Magnetic Nanoparticles for Concentrating and DetectingBacillus anthracisSpores in a Direct-Charge Transfer BiosensorIEEE Sensors Journal, 2008
- Dose Determination for Acute Salmonella Infection in PigsApplied and Environmental Microbiology, 2005
- Magnetic relaxation switches capable of sensing molecular interactionsNature Biotechnology, 2002
- INFECTIVE DOSE OF FOODBORNE PATHOGENS IN VOLUNTEERS: A REVIEWJournal of Food Safety, 2001