Endoscopic ultrasound‐guided fine‐needle biopsy histology with a 22‐gauge Franseen needle and fine‐needle aspiration liquid‐based cytology with a conventional 25‐gauge needle provide comparable diagnostic accuracy in solid pancreatic lesions
Authors:
Open Access
Abstract
Background and Aim: Fine‐needle biopsy (FNB) needles obtain more core samples and support the shift from cytologic to histologic evaluation; however, recent studies have proposed a superior diagnostic potential for liquid‐based cytology (LBC). This study compared the diagnostic ability of endoscopic ultrasound (EUS)‐guided FNB histology with a 22‐gauge Franseen needle (22G‐FNB‐H) and fine‐needle aspiration (FNA) LBC with a conventional 25‐gauge needle (25G‐FNA‐LBC).Methods: We analyzed 46 patients who underwent both 22G‐FNB‐H and 25G‐FNA‐LBC in the same lesion during the same endoscopic procedure. This study evaluated the diagnostic ability of each needle, diagnostic concordance between needles, and incremental diagnostic effect of both needles compared to using each needle alone.Results: The agreement rate for malignancy between both techniques was 93.5% (kappa value = 0.82). There was no significant difference in the diagnostic ability of both methods. 22G‐FNB‐H and 25G‐FNA‐LBC provided an incremental diagnostic accuracy in two (4.3%) cases and one (2.2%) case, respectively.Conclusion: Our study demonstrated that the diagnostic accuracy of 25G‐FNA‐LBC and 22G‐FNA‐H for solid pancreatic lesions were comparable. A conventional 25‐gauge needle that punctures lesions with ease can be used in difficult cases and according to the skill of the endoscopist.Keywords
This publication has 22 references indexed in Scilit:
- A meta-analysis of endoscopic ultrasound–fine-needle aspiration compared to endoscopic ultrasound–fine-needle biopsy: diagnostic yield and the value of onsite cytopathological assessmentEndoscopy International Open, 2017
- The presence of a cytopathologist increases the diagnostic accuracy of endoscopic ultrasound‐guided fine needle aspiration cytology for pancreatic adenocarcinoma: a meta‐analysisCytopathology, 2013
- The diagnostic accuracy of 22-gauge and 25-gauge needles in endoscopic ultrasound-guided fine needle aspiration of solid pancreatic lesions: a meta-analysisEndoscopy, 2013
- How Good Is Endoscopic Ultrasound–Guided Fine-Needle Aspiration in Diagnosing the Correct Etiology for a Solid Pancreatic Mass?Pancreas, 2013
- EUS-guided FNA for diagnosis of solid pancreatic neoplasms: a meta-analysisGastrointestinal Endoscopy, 2012
- Retrospective analysis of the utility of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic masses, using a 22-gauge or 25-gauge needle system: a multicenter experienceEndoscopy, 2009
- Prospective comparative study of the EUS guided 25‐gauge FNA needle with the 19‐gauge Trucut needle and 22‐gauge FNA needle in patients with solid pancreatic massesJournal of Gastroenterology and Hepatology, 2009
- Experimental endoscopy: objective evaluation of EUS needlesGastrointestinal Endoscopy, 2009
- Puncture of Solid Pancreatic Tumors Guided by Endoscopic Ultrasonography: A Pilot Study Series Comparing Trucut and 19-Gauge and 22-Gauge Aspiration NeedlesEndoscopy, 2005
- Endoscopic ultrasonography with guided fine needle aspiration biopsy in pancreatic diseaseGastrointestinal Endoscopy, 1992