FLAIR imaging using nonselective inversion pulses combined with slice excitation order cycling and k‐space reordering to reduce flow artifacts
- 24 July 2001
- journal article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 46 (2) , 354-364
Abstract
High‐signal artifacts produced by cerebrospinal fluid (CSF) flow can adversely affect fluid‐attenuated inversion recovery (FLAIR) imaging of the brain and spinal cord. This study explores the use of a nonslice‐selective inversion pulse to eliminate CSF flow artifacts together with a technique called “K‐space Reordered by Inversion‐time for each Slice Position” (KRISP) to achieve constant contrast in a multislice acquisition. Theory shows that with this method the CSF point spread function (PSF) has a minimum at the center and attenuated side lobes, providing CSF suppression, but residual edge signals remain. The PSF for brain is only mildly attenuated and signals for extended regions are not attenuated. KRISP FLAIR sequences were assessed in 15 patients (10 brain and five spinal cord cases). The images showed reduced CSF and blood flow artifacts and higher conspicuity of the cortex, meninges, ventricular system, brainstem, and cerebellum when compared with conventional FLAIR sequences. Magn Reson Med 46:354–364, 2001.Keywords
This publication has 9 references indexed in Scilit:
- Reduced power multislice MDEFT imagingJournal of Magnetic Resonance Imaging, 2000
- Brain Lesions: When Should Fluid-attenuated Inversion-Recovery Sequences Be Used in MR Evaluation?Radiology, 1999
- Three-dimensional fast fluid attenuated inversion recovery (3D fast FLAIR): a new MRI sequence which increases the detectable cerebral lesion load in multiple sclerosis.British Journal of Radiology, 1998
- Fluid-attenuated inversion recovery MR imaging: identification of protein concentration thresholds for CSF hyperintensity.American Journal of Roentgenology, 1997
- Magnetic resonance imaging: Spinal cord imaging with the turbo-fluid attenuated inversion recovery (FLAIR) pulse sequenceClinical Radiology, 1995
- MRI of the brain stem using fluid attenuated inversion recivery pulse sequencesNeuroradiology, 1993
- Use of Fluid‐Attenuated Inversion‐Recovery Pulse Sequences for Imaging the Spinal CordMagnetic Resonance in Medicine, 1992
- Use of Fluid Attenuated Inversion Recovery (FLAIR) Pulse Sequences in MRI of the BrainJournal of Computer Assisted Tomography, 1992
- Highly selective and π pulse generationJournal of Magnetic Resonance (1969), 1984