Safety and Feasibility of Pleural Cryobiopsy Compared to Forceps Biopsy During Semi-rigid Pleuroscopy
Authors:
- 28 March 2017
- journal article
- research article
- Published by Springer Nature in Lung
- Vol. 195 (3) , 371-375
Abstract
Background Pleural biopsy is often obtained in patients with undiagnosed exudative pleural effusion during pleuroscopy. Standard forceps have been traditionally used for the biopsy. Cryoprobes are being increasingly used for transbronchial lung biopsy as they obtain larger specimens and have less crush artifact. However, the safety and feasibility of cryoprobe biopsy compared to standard forceps for pleural biopsy has not been fully assessed. Objectives The objective of this study was to demonstrate the safety and feasibility of cryoprobe biopsy in the pleural space using semi-rigid pleuroscopy. Methods Patients with idiopathic exudative pleural effusions underwent pleuroscopy. The procedure was done in the endoscopy suite with full barrier precautions and moderate sedation. Pleural biopsies were initially taken with a 2.0-mm saw-toothed forceps followed by a 2.4-mm cryoprobe (ERBECRYO, ERBE, US). The freeze time for each biopsy was 3 s. Results There were a total of ten patients, five males and five females. The mean age was 69 years (SD ± 11 years). The mean number of biopsies taken from the parietal pleura using forceps was 4.5 (SD ± 1.5) vs. 3.7 (SD ± 1.4) using cryoprobe. The mean cumulative tissue volume with forceps biopsy was 80 cu. mm; the mean cumulative tissue volume with cryobiopsy was 320 cu. mm, p = 0.007. The diagnostic yields were similar in both the groups. There was no increased incidence of bleeding, chest wall injury, or pain using cryoprobe in any of the patients. Conclusion The use of cryoprobe for parietal pleural biopsy via semi-rigid pleuroscopy was feasible and safe in this small pilot study.Keywords
Funding Information
- the Guidance Fund for the Transformation of Sci-Tech Achievements in Guizhou Province ([2015]5016)
- the Bridging Project for the Enterprises and the Local Precious Flower R&D Groups in Guizhou Province ([2015]5711)
- the Special Funding Project for Sci-Tech Platforms and Talent Groups in Guizhou Province ([2013]4009)
- the Key Special Project of the Department of Science & Technology of Guizhou Province ([2009]6004)
This publication has 12 references indexed in Scilit:
- Intra-patient comparison of parietal pleural biopsies by rigid forceps, flexible forceps and cryoprobe obtained during medical thoracoscopy: a prospective series of 80 cases with pleural effusionBMC Pulmonary Medicine, 2016
- Transbronchial cryobiopsy in diffuse parenchymal lung diseasesCurrent Opinion in Pulmonary Medicine, 2016
- Transbronchial Cryobiopsy Can Diagnose Constrictive Bronchiolitis in Veterans of Recent Conflicts in the Middle EastAmerican Journal of Respiratory and Critical Care Medicine, 2016
- Increasing Diagnostic Value of Transbronchial Lung CryobiopsyRespiration, 2016
- Comparison of Transbronchial and Cryobiopsies in Evaluation of Diffuse Parenchymal Lung DiseaseJournal of Bronchology & Interventional Pulmonology, 2016
- Pleuroscopic CryobiopsyJournal of Bronchology & Interventional Pulmonology, 2015
- Feasibility and safety of parietal pleural cryobiopsy during semi‐rigid thoracoscopyThe Clinical Respiratory Journal, 2015
- Pleuroscopic cryoprobe biopsies of the pleura: A feasibility and safety studyRespirology, 2014
- Prospective evaluation of flex‐rigid pleuroscopy for indeterminate pleural effusion: Accuracy, safety and outcomeRespirology, 2007
- Investigation of Pleural EffusionChest, 1998