Assessment of bioaerosols in tuberculosis high-risk areas of health care facilities in central Thailand
Open Access
- 1 April 2018
- journal article
- research article
- Published by Walter de Gruyter GmbH in Asian Biomedicine
- Vol. 12 (2) , 55-63
Abstract
Background: Long-term surveillance of airborne bioaerosols in health care facilities is required to protect the health of patients and health care workers. Feasible methods to measure airborne bioaerosol concentrations and determine associated environmental factors may help to avoid nosocomial tuberculosis (TB). Objectives: To describe the concentrations and size of airborne bioaerosols and to identify the potential contributors to indoor airborne bioaerosols in TB high-risk areas in health care facilities. Methods: We conducted a cross-sectional study in 7 large health care facilities located in Bangkok and nearby in central Thailand using a 6-stage Andersen cascade impactor to collect viable airborne bioaerosols that were quantified using culture techniques. Environmental parameters were determined using a tracer gas technique with an indoor air quality meter. Other potential factors were assessed using a questionnaire. Results: The mean indoor airborne bacterial and fungal concentrations were 596.1 and 521.2 colony-forming units (cfu)/m 3 , respectively, and the mean outdoor airborne bacterial and fungal concentrations were 496.5 and 650.1 cfu/m 3 , respectively. The majority of airborne bioaerosols were in respirable sizes. The indoor-to-outdoor ratios were 1.2 for bacteria and 0.8 for fungi. Air change rate was inversely correlated with indoor airborne bioaerosol concentrations, whereas emergency department central-type air conditioners and relative humidity were positively correlated with the indoor airborne bioaerosol concentrations ( P < 0.05). Conclusions: High indoor bioaerosol concentrations found in the health care facilities suggest that it is imperative to improve the indoor air quality. Improved air change rate and avoiding use of central-type air-conditioning systems may reduce bioaerosol concentrations.Keywords
This publication has 16 references indexed in Scilit:
- Sources of airborne microorganisms in the built environmentMicrobiome, 2015
- Microbiological assessment of indoor air quality at different hospital sitesResearch in Microbiology, 2015
- Pilot study to detect airborne Mycobacterium tuberculosis exposure in a South African public healthcare facility outpatient clinicJournal of Hospital Infection, 2015
- Microbial Contamination on Used Surgical Masks among Hospital Personnel and Microbial Air Quality in their Working Wards: A Hospital in BangkokOman Medical Journal, 2014
- Assessment of the Levels of Airborne Bacteria, Gram-Negative Bacteria, and Fungi in Hospital LobbiesInternational Journal of Environmental Research and Public Health, 2013
- Inadequate hospital ventilation system increases the risk of nosocomial Mycobacterium tuberculosisJournal of Hospital Infection, 2012
- Concentration Profiles of AirborneMycobacterium tuberculosisin a HospitalAerosol Science and Technology, 2008
- Airborne microbiological characteristics in public buildings of KoreaBuilding and Environment, 2007
- Use of temporal/seasonal- and size-dependent bioaerosol data to characterize the contribution of outdoor fungi to residential exposuresScience of The Total Environment, 2005
- The National Human Activity Pattern Survey (NHAPS): a resource for assessing exposure to environmental pollutantsJournal of Exposure Science & Environmental Epidemiology, 2001