Phosphorus Removal and Carbon Dioxide Capture in a Pilot Conventional Septic System Upgraded with a Sidestream Steel Slag Filter
Open Access
Abstract
The objective of this work was to demonstrate the removal of the phosphorus and carbon dioxide capture potential of a conventional septic system upgraded with a sidestream steel slag filter used in recirculation mode. A pilot scale sidestream experiment was conducted with two septic tank and drainfield systems, one with and one without a sidestream slag filter. The experimental system was fed with real domestic wastewater. Recirculation ratios of 25%, 50% and 75% were tested. Limestone soils and non-calcareous soils were used as drainfield media. The tested system achieved a satisfactory compromise between phosphorus removal and pH at the effluent of the septic tank, thus eliminating the need for a neutralization step. The phosphorus removal efficiency observed in the second compartment of the septic tank was 30% in the slag filter upgraded system, compared to −3% in the control system. The slag filter reached a phosphorus retention of 105 mg/kg. The drainfield of non-calcareous soils achieved very high phosphorus removal in both control and upgraded systems. In the drainfield of limestone soil, the slag filtration reduced the groundwater phosphorus contamination load by up to 75%. The removal of chemical oxygen demand of the drainfields was not affected by the pH rise induced by the slag filter. Phosphorus removal in the septic tank with a slag filter was attributed to either sorption on newly precipitated calcium carbonate, or the precipitation of phosphate minerals, or both. Recirculation ratio design criteria were proposed based on simulations. Simulations showed that the steel slag filter partly inhibited the biological production of carbon dioxide in the septic tank. The influent alkalinity strongly influenced the recirculation ratio needed to raise the pH in the septic tank. The recirculation mode allowed clogging mitigation compared to a mainstream configuration, because an important part of chemical precipitation occurred in the septic tank. The control septic tank produced carbon dioxide, whereas the slag filter-upgraded septic tank was a carbon dioxide sink.Keywords
All Related Versions
Funding Information
- National Sciences and Engineering Research Council of Canada (RDCPJ476673-14)
This publication has 29 references indexed in Scilit:
- Steel slag filter design criteria for phosphorus removal from wastewater in decentralized applicationsWater Research, 2018
- A review of the fate and transport of nitrogen, phosphorus, pathogens, and trace organic chemicals in septic systemsCritical Reviews in Environmental Science and Technology, 2017
- Alternative filter material removes phosphorus and mitigates greenhouse gas emission in horizontal subsurface flow filters for wastewater treatmentEcological Engineering, 2015
- Improving phosphorus removal of conventional septic tanks by a recirculating steel slag filterWater Quality Research Journal, 2015
- Phosphorus Removal from Lake Water Using Basic Oxygen Furnace Slag: System Performance and Characterization of Reaction ProductsEnvironmental Engineering Science, 2014
- Effect of organic load on phosphorus and bacteria removal from wastewater using alkaline filter materialsWater Research, 2013
- An Evaluation of Several In-Lake Restoration Techniques to Improve the Water Quality Problem (Eutrophication) of Saint-Augustin Lake, Quebec, CanadaEnvironmental Management, 2012
- EAF Steel Slag Filters for Phosphorus Removal from Milk Parlor Effluent: The Effects of Solids Loading, Alternate Feeding Regimes and In-Series DesignWater, 2010
- Developments in CO2 mineral carbonation of oil shale ashJournal of Hazardous Materials, 2010
- Review of Phosphate Mobility and Persistence in 10 Septic System PlumesGroundwater, 1998