Abstract
Based on a simplified Monte Carlo simulation model of electron scattering and characteristic x‐ray excitation of a multicomponent film on a substrate, a calculation method with an iteration approach was developed to transform the x‐ray intensity ratios measured by an electron probe microanalyzer into the chemical composition of the thin film on the substrate. The calculation of the characteristic fluorescence is also included in the simulation. The calculation results of compositions for several specimens agree well with measured data. Copyright © 2001 John Wiley & Sons, Ltd.