Comparison and reproducibility of corneal thickness and curvature readings obtained by the Galilei and the Orbscan II analysis systems
Authors:
- Claude KaufmannCKClaude Kaufmann
- Michael A. ThielMTMichael A. Thiel
- 1 October 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (10) , 1742-1747
Abstract
To compare central corneal thickness (CCT) and keratometry readings using the Galilei dual Scheimpflug analyzer, the Orbscan II anterior segment analysis system, and the Sonogage ultrasound (US) pachymeter. Lucerne Eye Clinic, Cantonal Hospital, Lucerne, Switzerland. In a prospective single-center study, 85 eyes of 45 healthy volunteers were examined with the Orbscan II and Galilei systems in random order followed by Sonogage US pachymetry. The CCT and keratometry measurements were compared using a paired t test. To assess the intraobserver and interobserver reproducibility of the 2 keratometers, 9 volunteers were examined 3 times by 4 independent observers and the intraclass correlation coefficient (ICC) was calculated. The mean CCT was 551.7 microm+/-36.6 (SD) with the Galilei, 554.8+/-45.1 microm with the Orbscan II, and 558.5+/-38.4 microm with the Sonogage. The CCT readings of the Galilei and Orbscan II did not differ significantly (P= .12). The mean keratometry readings with the Galilei and Orbscan II were similar, although both the steep (Ks) and flat (Kf) axes tended to be flatter with the Galilei system. The ICCs for CCT, Kf, and Ks were high with both keratometers (0.98, 0.97, 0.84 for Galilei and 0.97, 0.96, 0.95 for Orbscan II, respectively), indicating that variation in measurements was mainly due to true subject-to-subject variation rather than observer error. Keratometry and pachymetry readings with the Galilei and Orbscan II systems showed good concordance and high reproducibility, which would allow the examinations to be delegated to nonmedical personnel.Keywords
This publication has 21 references indexed in Scilit:
- Agreement and Repeatability of Central Thickness Measurement in Normal Corneas Using Ultrasound Pachymetry and the OCULUS PentacamCornea, 2005
- Repeatability and Reproducibility of Central Corneal Thickness Measurement With Pentacam, Orbscan, and UltrasoundOptometry and Vision Science, 2005
- Orbscan computerized topography: Attributes, applications, and limitationsJournal of Cataract & Refractive Surgery, 2005
- Central corneal thickness measurements with partial coherence interferometry, ultrasound, and the Orbscan systemOphthalmology, 2004
- Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thicknessBritish Journal of Ophthalmology, 2004
- The Repeatability of Corneal Thickness MeasuresCornea, 2000
- Postoperative complications in laser in situ keratomileusisCurrent Opinion in Ophthalmology, 2000
- Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography systemBritish Journal of Ophthalmology, 1999
- Orbscan pachymetryOphthalmology, 1999
- Delayed onset keratectasia following laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 1999