Mechanical properties of the fetal ductus venosus and umbilical vein
- 1 July 1998
- journal article
- research article
- Published by Springer Nature in Heart and Vessels
- Vol. 13 (4) , 175-180
Abstract
During fetal circulatory compromise, velocity pulsations in the precordial veins increase and are commonly transmitted through the ductus venosus into the umbilical vein, indicating a serious prognosis. The nature of the pulsations and their transmission into the periphery, specifically the umbilical vein, is poorly understood. We present information on the mechanical properties of fetal veins as a basis for describing the pulse wave propagation. Five fetal sheep livers with connecting veins (gestational age 0.8–0.9) were studied in vitro. The transmural pressure, obtained with a fluid-filled catheter, was reduced stepwise from 10.3 to 0mmHg, and the diameter determined by ultrasonography. Each data set was fitted to an exponential function to determine the stiffness parameter and the area at a standard pressure, which we proposed to be 5 mmHg for the fetal venous circulation. The stiffness parameter was 6.2 ± 1.8 at the ductus venosus outlet, 3.4 ± 1.3 at the ductus venosus inlet, and 4.0 ± 1.0 in the umbilical vein. Correspondingly, values for compliance and pulse wave velocity for the three venous sections were established for a physiological pressure range. The estimated pulse wave velocity of 1–3m/s is comparable with values estimated for veins in adults. The mechanical properties of fetal veins are comparable with those described for veins later in life. The stiffness parameter represents the elastic properties at all pressure levels and conveniently permits inference of compliance and pulse wave velocity.Keywords
This publication has 40 references indexed in Scilit:
- Validation of diameter measurements by ultrasound: intraobserver and interobserver variations assessed in vitro and in fetal sheepUltrasound in Obstetrics & Gynecology, 1999
- Fetal neurosonography: should it be routine? Should it be detailed?Ultrasound in Obstetrics & Gynecology, 1998
- Ductus venosus agenesis prevents transmission of central venous pulsations to the umbilical vein in fetal sheepUltrasound in Obstetrics & Gynecology, 1998
- Fetal echocardiography guidelines to predict survival of fetuses with ascitesUltrasound in Obstetrics & Gynecology, 1996
- Umbilical venous doppler velocity pulsations and inferior vena cava pressure elevations in fetal lambsObstetrics & Gynecology, 1996
- Computational analysis of the ductus venosus fluid dynamics based on Doppler measurementsUltrasound in Medicine & Biology, 1996
- Experimental Approaches on Measuring the Mechanical Properties and Constitutive Laws of Arterial WallsJournal of Biomechanical Engineering, 1993
- Evaluation of the Preload Condition of the Fetus by Inferior Vena Caval Blood Flow PatternFetal Diagnosis and Therapy, 1990
- Circulatory Changes in Fetuses with Imminent AsphyxiaNeonatology, 1986
- The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new modelJournal of Biomechanics, 1984