Fully 3D iterative scatter-corrected OSEM for HRRT PET using a GPU
Authors:
- Jong Chul YeJYJong Chul Ye
- 19 July 2011
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (15) , 4991-5009
Abstract
Accurate scatter correction is especially important for high-resolution 3D positron emission tomographies (PETs) such as high-resolution research tomograph (HRRT) due to large scatter fraction in the data. To address this problem, a fully 3D iterative scatter-corrected ordered subset expectation maximization (OSEM) in which a 3D single scatter simulation (SSS) is alternatively performed with a 3D OSEM reconstruction was recently proposed. However, due to the computational complexity of both SSS and OSEM algorithms for a high-resolution 3D PET, it has not been widely used in practice. The main objective of this paper is, therefore, to accelerate the fully 3D iterative scatter-corrected OSEM using a graphics processing unit (GPU) and verify its performance for an HRRT. We show that to exploit the massive thread structures of the GPU, several algorithmic modifications are necessary. For SSS implementation, a sinogram-driven approach is found to be more appropriate compared to a detector-driven approach, as fast linear interpolation can be performed in the sinogram domain through the use of texture memory. Furthermore, a pixel-driven backprojector and a ray-driven projector can be significantly accelerated by assigning threads to voxels and sinograms, respectively. Using Nvidia's GPU and compute unified device architecture (CUDA), the execution time of a SSS is less than 6 s, a single iteration of OSEM with 16 subsets takes 16 s, and a single iteration of the fully 3D scatter-corrected OSEM composed of a SSS and six iterations of OSEM takes under 105 s for the HRRT geometry, which corresponds to acceleration factors of 125× and 141× for OSEM and SSS, respectively. The fully 3D iterative scatter-corrected OSEM algorithm is validated in simulations using Geant4 application for tomographic emission and in actual experiments using an HRRT.Keywords
This publication has 22 references indexed in Scilit:
- Ultra Fast Symmetry and SIMD-Based Projection-Backprojection (SSP) Algorithm for 3-D PET Image ReconstructionIEEE Transactions on Medical Imaging, 2007
- A solution to arc correction in cylindrical PET scanner2005
- GATE: a simulation toolkit for PET and SPECTPhysics in Medicine & Biology, 2004
- Optimization of a fully 3D single scatter simulation algorithm for 3D PETPhysics in Medicine & Biology, 2004
- Cone-beam reprojection using projection-matricesIEEE Transactions on Medical Imaging, 2003
- Scatter correction techniques in 3D PET: a Monte Carlo evaluationIEEE Transactions on Nuclear Science, 1999
- Developments in component-based normalization for 3D PETPhysics in Medicine & Biology, 1999
- Accelerated image reconstruction using ordered subsets of projection dataIEEE Transactions on Medical Imaging, 1994
- An Improved Algorithm for Reprojecting Rays through Pixel ImagesIEEE Transactions on Medical Imaging, 1982
- Über die Streuung von Strahlung durch freie Elektronen nach der neuen relativistischen Quantendynamik von DiracZeitschrift für Physik, 1929