Abstract
Surface plasmon resonance imaging (SPRi) is a label-free technique used for the quantitation of binding affinities and concentrations for a wide variety of target molecules. Although SPRi is capable of determining binding constants for multiple ligands in parallel, current commercial instruments are limited to a single analyte stream on multiple ligand spots. Measurement of binding kinetics requires the serial introduction of different analyte concentrations; such repeated experiments are conducted manually and are therefore time-intensive. To address these challenges, we have developed an integrated microfluidic array using soft lithography techniques for high-throughput SPRi-based detection and determination of binding affinities of antibodies against protein targets. The device consists of 264 element-addressable chambers isolated by microvalves. The resulting 700 pL chamber volumes, combined with a serial dilution network for simultaneous interrogation of up to six different analyte concentrations, allow for further speeding detection times. To test for device performance, human α-thrombin was immobilized on the sensor surface and anti-human α-thrombin IgG was injected across the surface at different concentrations. The equilibrium dissociation constant was determined to be 5.0 ± 1.9 nM, which agrees well with values reported in the literature. The interrogation of multiple ligands to multiple analytes in a single device was also investigated and samples were recovered with no cross-contamination. Since each chamber can be addressed independently, this array is capable of interrogating binding events from up to 264 different immobilized ligands against multiple analytes in a single experiment. The development of high-throughput protein analytic measurements is a critical technology for systems approaches to biology and medicine.Keywords
This publication has 41 references indexed in Scilit:
- Microchannel chips for the multiplexed analysis of human immunoglobulin G–antibody interactions by surface plasmon resonance imagingAnalytical and Bioanalytical Chemistry, 2008
- Extracting kinetic rate constants from surface plasmon resonance array systemsAnalytical Biochemistry, 2008
- Surface plasmon resonance imaging for affinity analysis of aptamer–protein interactions with PDMS microfluidic chipsAnalytical and Bioanalytical Chemistry, 2007
- SPR microscopy and its applications to high-throughput analyses of biomolecular binding events and their kineticsBiomaterials, 2007
- Higher-throughput, label-free, real-time molecular interaction analysisAnalytical Biochemistry, 2007
- Exploring “one-shot” kinetics and small molecule analysis using the ProteOn XPR36 array biosensorAnalytical Biochemistry, 2006
- High-throughput affinity ranking of antibodies using surface plasmon resonance microarraysAnalytical Biochemistry, 2006
- Development of a novel electrokinetically driven microfluidic immunoassay for the detection of Helicobacter pyloriAnalytica Chimica Acta, 2005
- A new surface plasmon resonance sensor for high-throughput screening applicationsBiosensors and Bioelectronics, 2005
- Notizen: Radiative Decay of Non Radiative Surface Plasmons Excited by LightZeitschrift für Naturforschung A, 1968