Noninvasive Monitoring of Carbon Dioxide During Mechanical Ventilation in Older Children: End-Tidal Versus Transcutaneous Techniques
Authors:
- John W. BerkenboschJBJohn W. Berkenbosch
- Janet LamJLJanet Lam
- Randall S. BurdRBRandall S. Burd
- Joseph D. TobiasJTJoseph D. Tobias
- 1 June 2001
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 92 (6) , 1427-1431
Abstract
We prospectively compared the accuracy of end-tidal CO2 (ETco2) and transcutaneous CO2 (TCco2) monitoring in older pediatric patients (4 yr or older) receiving mechanical ventilation for respiratory failure. ETco2 and TCco2 were simultaneously monitored and compared with arterial CO2 (Paco2) values when arterial blood gas analysis was performed. Eighty-two sample sets were compared. The ETco2 to Paco2 difference was 6.4 ± 6.3 mm Hg, whereas the TCco2 to Paco2 difference was 2.6 ± 2.0 mm Hg (P < 0.0001). The absolute difference of ETco2 and Paco2 was 5 or less in 47 of 82 measurements, whereas the absolute TCco2 to Paco2 difference was 5 or less in 76 of 82 measurements (P < 0.00001). Regression analysis of ETco2 and Paco2 values revealed a correlation coefficient of 0.5418 and an r value of 0.8745. Regression analysis of TCco2 and Paco2 values revealed a correlation coefficient of 1.0160 and an r value of 0.9693. Bland-Altman analysis revealed a bias of −5.68 with a precision of ±6.93 when comparing ETco2 with Paco2 and a bias of 0.02 with a precision of ±3.27 when comparing TCco2 and Paco2 (P < 0.00001). TCco2 monitoring provided an accurate estimation of Paco2 over a wide range of CO2 values and was superior to ETco2 monitoring in older pediatric patients with respiratory failure. TCco2 monitoring may be considered as a useful adjunct to monitoring of ventilation in this patient population.Keywords
This publication has 11 references indexed in Scilit:
- Transcutaneous Monitoring of Carbon Dioxide Tension After Cardiothoracic Surgery in Infants and ChildrenAnesthesia & Analgesia, 1999
- Noninvasive monitoring of end-tidal CO2 via nasal cannulas in spontaneously breathing children during the perioperative periodCritical Care Medicine, 1994
- Accuracy of Capnography in Nonintubated Surgical PatientsChest, 1992
- Estimation of arterial carbon dioxide by end‐tidal and transcutaneous P measurements in ventilated childrenPediatric Pulmonology, 1992
- Transcutaneous Pco2 and Po2: A multicenter study of accuracyJournal of Clinical Monitoring and Computing, 1990
- Comparison of Arterial-End-Tidal PCO2 Difference and Dead Space/Tidal Volume Ratio in Respiratory FailureChest, 1987
- Comparison of noninvasive measurements of carbon dioxide tension during withdrawal from mechanical ventilationCritical Care Medicine, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Estimation of Paco2 by two noninvasive methods in the critically ill newborn infantThe Journal of Pediatrics, 1985
- Measurement of transcutaneous PCO2 in critically ill patientsResuscitation, 1982