Radiation-Induced Eye Lens Changes and Risk for Cataract in Interventional Cardiology
Authors:
- O. Ciraj-BjelacOCO. Ciraj-Bjelac
- M. RehaniMRM. Rehani
- A. MinamotoAMA. Minamoto
- K.H. SimKSK.H. Sim
- H.B. LiewHLH.B. Liew
- E. VanoEVE. Vano
- 31 October 2012
- journal article
- Published by S. Karger AG in Cardiology
- Vol. 123 (3) , 168-171
Abstract
Background: Recent studies have reported a significant increase in eye lens opacities among staff in the cardiac catheterization laboratory but indicated further studies are needed to confirm the findings. Objective: To evaluate the prevalence of opacities in eyes of cardiologists, radiographers and nurses working in interventional cardiology. Methods: The eyes of 52 staff in interventional cardiology facilities and 34 age- and sex-matched unexposed controls were screened in a cardiology conference held in Kuala Lumpur by dilated slit-lamp examination, and posterior lens changes were graded. Individual cumulative lens X-ray exposures were calculated from responses to a questionnaire in terms of workload and working practice. Results: The prevalence of posterior lens opacities among interventional cardiologists was 53%, while in nurses and radiographers it was 45%. Corresponding relative risks were 2.6 (95% CI: 1.2–5.4) and 2.2 (95% CI: 0.98–4.9), for interventional cardiologists and support staff, respectively. Conclusions: This study confirms a statistically significant increase in radiation-associated posterior lens changes in the eyes of interventional cardiology staff.Keywords
This publication has 11 references indexed in Scilit:
- Radiation and cataractRadiation Protection Dosimetry, 2011
- Personal dosimetry for interventional operators: when and how should monitoring be done?British Journal of Radiology, 2011
- Risk for radiation‐induced cataract for staff in interventional cardiology: Is there reason for concern?Catheterization and Cardiovascular Interventions, 2010
- Radiation Cataract Risk in Interventional Cardiology PersonnelRadiation Research, 2010
- Scatter and staff dose levels in paediatric interventional cardiology: a multicentre studyRadiation Protection Dosimetry, 2010
- Minimising radiation exposure to physicians performing fluoroscopically guided cardiac catheterisation procedures: a reviewRadiation Protection Dosimetry, 2009
- Eye Lens Exposure to Radiation in Interventional Suites: Caution Is WarrantedRadiology, 2008
- External factors in the development of cataractEye, 2005
- Radiation doses to the legs of radiologists performing interventional procedures: are they a cause for concern?British Journal of Radiology, 2003
- Patient radiation doses during cardiac catheterization procedures.British Journal of Radiology, 1998