Through Skull Fluorescence Imaging of the Brain in a New Near-Infrared Window

Authors:
  • GHGuosong Hong
    Guosong Hong
  • SDShuo Diao
    Shuo Diao
  • JCJunlei Chang
    Junlei Chang
  • AAAlexander L. Antaris
    Alexander L. Antaris
  • CCChangxin Chen
    Changxin Chen
  • BZBo Zhang
    Bo Zhang
  • SZSu Zhao
    Su Zhao
  • DADmitriy N. Atochin
    Dmitriy N. Atochin
  • PHPaul L. Huang
    Paul L. Huang
  • KAKatrin I. Andreasson
    Katrin I. Andreasson
  • CKCalvin J. Kuo
    Calvin J. Kuo
  • HDHongjie Dai
    Hongjie Dai

Abstract
To date, brain imaging has largely relied on X-ray computed tomography and magnetic resonance angiography with limited spatial resolution and long scanning times. Fluorescence-based brain imaging in the visible and traditional near-infrared regions (400-900 nm) is an alternative but currently requires craniotomy, cranial windows and skull thinning techniques, and the penetration depth is limited to 1-2 mm due to light scattering. Here, we report through-scalp and through-skull fluorescence imaging of mouse cerebral vasculature without craniotomy utilizing the intrinsic photoluminescence of single-walled carbon nanotubes in the 1.3-1.4 micrometre near-infrared window. Reduced photon scattering in this spectral region allows fluorescence imaging reaching a depth of >2 mm in mouse brain with sub-10 micrometre resolution. An imaging rate of ~5.3 frames/s allows for dynamic recording of blood perfusion in the cerebral vessels with sufficient temporal resolution, providing real-time assessment of blood flow anomaly in a mouse middle cerebral artery occlusion stroke model.