Observations on the collection and handling of blood samples for N.E.F.A. estimation

Authors:
  • DFD. V. I. Fairweather
    D. V. I. Fairweather
  • RLR. Layton
    R. Layton

Abstract
The effect upon the results of estimating plasma or serum non-esterified fatty acids (N.E.F.A.) assay by different methods of collecting blood samples and subsequent differences in sample storage and time of assay have been studied. Standardization of technique is advised and the use of chilled heparinized tubes, with separation of the sample within one hour of collection and assay on the day of collection is advocated.

This publication has 11 references indexed in Scilit: