Abstract
It is shown experimentally that a microplasma created by a microstructured electrode array is sensitive to sound pressure. In this paper, two electrode architectures are used to create the microplasma. The sensitivity of these microplasma microphones, close to 0.4 nA/Pa, is estimated using a waveguide and a calibration method by comparison with a reference microphone. An empirical expression of the acoustic pressure sensitivity of microdischarges is proposed. The predictions of this empirical model are in good agreement with the experimental data.Keywords
Funding Information
- Conseil Régional des Pays de la Loire
This publication has 24 references indexed in Scilit:
- Modeling of a corona discharge microphoneJournal of Physics D: Applied Physics, 2013
- Self-oscillationPhysics Reports, 2013
- Discharge resistance and power dissipation in the self-pulsing regime of micro-hollow cathode dischargesPlasma Sources Science and Technology, 2011
- Acoustics and gas discharges: applications to loudspeakersJournal of Physics D: Applied Physics, 1987
- Modeling of a dc glow plasma loudspeakerThe Journal of the Acoustical Society of America, 1987
- An anemometer for highly turbulent or recirculating flowsExperiments in Fluids, 1987
- Corona Discharges1978
- STL–Ionophone: Transducer properties and constructionThe Journal of the Acoustical Society of America, 1975
- Glow Discharge MicrophoneReview of Scientific Instruments, 1970
- The Interaction of A Sound Wave with A Point-to-Plane Corona DischargeThe Journal of the Acoustical Society of America, 1953