Studies combining immune checkpoint inhibitors with external beam radiation have shown a therapeutic advantage over each modality alone. The purpose of these works is to evaluate the potential of targeted delivery of high LET radiation to the tumor microenvironment via an immune checkpoint inhibitor. The impact of protein concentration on the distribution of 111In-DTPA-anti-PD-L1-BC, an 111In-antibody conjugate targeted to PD-L1, was evaluated in an immunocompetent mouse model of breast cancer. 225Ac-DOTA-anti-PD-L1-BC was evaluated by both macroscale (ex vivo biodistribution) and microscale (alpha-camera images at a protein concentration determined by the 111In data. The evaluation of 111In-DTPA-anti-PD-L1-BC at 1, 3, and 10 mg/kg highlighted the impact of protein concentration on the distribution of the labeled antibody, particularly in the blood, spleen, thymus, and tumor. Alpha-camera images for the microscale distribution of 225Ac-DOTA-anti-PD-L1-BC showed a uniform distribution in the liver while highly non-uniform distributions were obtained in the thymus, spleen, kidney, and tumor. At an antibody dose of 3 mg/kg, the liver was dose-limiting with an absorbed dose of 738 mGy/kBq; based upon blood activity concentration measurements, the marrow absorbed dose was 29 mGy/kBq. These studies demonstrate that 225Ac-DOTA-anti-PD-L1-BC is capable of delivering high LET radiation to PD-L1 tumors. The use of a surrogate SPECT agent, 111In-DTPA-anti-PD-L1-BC, is beneficial in optimizing the dose delivered to the tumor sites. Furthermore, an accounting of the microscale distribution of the antibody in preclinical studies was essential to the proper interpretation of organ absorbed doses and their likely relation to biologic effect.Keywords
Funding Information
- National Institutes of Health (R01 CA 187037)
This publication has 43 references indexed in Scilit:
- Safety and Activity of Anti–PD-L1 Antibody in Patients with Advanced CancerThe New England journal of medicine, 2012
- Safety, Activity, and Immune Correlates of Anti–PD-1 Antibody in CancerThe New England journal of medicine, 2012
- A nephron-based model of the kidneys for macro-to-micro α-particle dosimetryPhysics in Medicine & Biology, 2012
- Radiation-Associated Kidney InjuryInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Radioimmunotherapy of Breast Cancer Metastases with α-Particle Emitter 225Ac: Comparing Efficacy with 213Bi and 90YCancer Research, 2009
- MIRD Pamphlet No. 21: A Generalized Schema for Radiopharmaceutical Dosimetry—Standardization of NomenclatureJournal of Nuclear Medicine, 2009
- Biodistributions of 177Lu- and 111In-Labeled 7E11 Antibodies to Prostate-Specific Membrane Antigen in Xenograft Model of Prostate Cancer and Potential Use of 111In-7E11 as a Pre-therapeutic Agent for 177Lu-7E11 RadioimmunotherapyMolecular Imaging and Biology, 2008
- 213Bi (α-Emitter)–Antibody Targeting of Breast Cancer Metastases in theneu-N Transgenic Mouse ModelCancer Research, 2008
- An Improved Method for the Production of Ac‐225/Bi‐213 from Th‐229 for Targeted Alpha TherapySolvent Extraction and Ion Exchange, 2007