DFT-Based Phasor Estimation for Removal of the Effect of Multiple DC Components
- 12 April 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (6) , 2901-2909
Abstract
A current sampled signal in a faulted transmission line can contain multiple dc components, namely a primary decaying dc component (DDC), a secondary DDC, an auxiliary DDC, and a bias DDC, and these may be due to a faulted line, current transformer, internal transformer, and analog-to-digital converter in the numerical relay, respectively. The intensity of the primary DDC is much higher than those of other DDCs. The elimination of the phasor-estimation error due to the primary DDC is the main issue in numerical relays, where the presence of other DDCs can deteriorate the phasor-estimation accuracy. This paper proposes a discrete Fourier transform (DFT)-based method using a second-order finite-impulse response (FIR) notch filter to combine multiple DDCs as a certain DDC through DFT. The FIR notch filter is designed to minimize the calculation complexity of the identification. Phasor-estimation errors that are due to the multiple DDCs are corrected by identifying the combined DDC. The proposed method can be applied for both full-cycle DFT (FCDFT) and half cycle DFT. The feasibility of the proposed FCDFT-based method is compared with those of conventional FCDFT-based methods using simulations on DDCs, harmonics, noise, and a faulted transmission line.Keywords
Funding Information
- Korea Electric Power Corporation through Korea Electrical Engineering and Science Research Institute (R15XA03-37)
This publication has 10 references indexed in Scilit:
- Noise Analysis of Power System Frequency Estimated From Angle Difference of Discrete Fourier Transform CoefficientIEEE Transactions on Power Delivery, 2014
- A Full- and Half-Cycle DFT-based technique for fault current filtering2010
- Fourier Transform-Based Modified Phasor Estimation Method Immune to the Effect of the DC OffsetsIEEE Transactions on Power Delivery, 2009
- Discrete-Fourier-transform-based technique for removal of decaying DC offset from phasor estimatesIEE Proceedings - Generation, Transmission and Distribution, 2003
- An analytic method for measuring accurate fundamental frequency componentsIEEE Transactions on Power Delivery, 2002
- Removal of DC offset in current and voltage signals using a novel Fourier filter algorithmIEEE Transactions on Power Delivery, 2000
- Removal of DC-offset in current waveforms using digital mimic filteringIEEE Transactions on Power Delivery, 1995
- Experimental evaluation of EMTP-based current transformer models for protective relay transient studyIEEE Transactions on Power Delivery, 1994
- Initial results in Prony analysis of power system response signalsIEEE Transactions on Power Systems, 1990
- Transient Compensation of Current TransformersIEEE Transactions on Power Apparatus and Systems, 1978