Leakage current characteristics and ageing assessment technology of roof arrester under ultra harmonics overvoltage
Open Access
- 27 August 2021
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 7 (2) , 346-356
Abstract
The large leakage current of the roof arrester caused by the high‐frequency resonant overvoltage on the high‐speed train occurs intermittently, which will cause the arrester to overheat locally. In this work, the overheating issue of the arrester under Ultra Harmonics Overvoltage is studied. Then, the relationship between the active power and the voltage (including amplitude and frequency) of the arrester is investigated, and the impact mechanism of the harmonic voltage on the overheating fault of the arrester is analysed based on experiments in this work. It is found that the total leakage current of the arrester is proportional to the amplitude and frequency of the applied voltage. The internal resistance of the arrester is independent of the amplitude of the voltage, but it will decrease with the increase of the frequency. The main reason that leads to thermal breakdown of the arrester valve under high‐frequency harmonic voltage is the heating power elevation of the arrester valve. The research study can provide theoretical basis and data support for the design, type selection and monitoring of the high‐speed train roof arrester.Keywords
Funding Information
- National Natural Science Foundation of China (51907003)
This publication has 22 references indexed in Scilit:
- Possible Measures to Enhance the Performance of Metal–Oxide Arresters in the EHV Network Under Very Fast TransientsIEEE Transactions on Power Delivery, 2015
- Criminal Law of the People's Republic of ChinaChinese Law & Government, 2012
- Impact of High-Voltage Primary Supply Lines in the 2 $\times$ 25 kV–50 Hz Railway System on the Equivalent Impedance at Pantograph TerminalsIEEE Transactions on Power Delivery, 2011
- Modelling of metal oxide arrester for very fast transientsIET Science, Measurement & Technology, 2011
- Harmonic Analysis of the Korean High-Speed Railway Using the Eight-Port Representation ModelIEEE Transactions on Power Delivery, 2006
- Harmonic Resonance Mode AnalysisIEEE Transactions on Power Delivery, 2005
- A simplified model for zinc oxide surge arrestersIEEE Transactions on Power Delivery, 1999
- Development of high gradient zinc oxide nonlinear resistors and their application to surge arrestersIEEE Transactions on Power Delivery, 1998
- Very high frequency overvoltages at open air EHV substations during disconnect switch operationsIEEE Transactions on Power Delivery, 1996