Sensitive electrochemical immunoassay of a biomarker based on biotin-avidin conjugated DNAzyme concatamer with signal tagging
Authors:
- 29 May 2013
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 3 (32) , 13451-13456
Abstract
This work reports a new electrochemical immunoassay protocol with signal amplification for the sensitive detection of a biomarker (carcinoembryonic antigen, CEA, used in this case) by coupling hemin/G-quadruplex-constructed DNAzyme concatamer with the biotin-avidin amplification system. Initially, polyclonal rabbit anti-human CEA antibody (pAb1) was immobilized onto a gold nanoparticle-modified glassy carbon electrode, which was used for the capture of target CEA, and biotin-labeled mouse anti-human monoclonal CEA antibody (bio-mAb2) was then used as a secondary antibody for the formation of the sandwiched immunocomplex in the presence of target CEA on the pAb1-modified electrode. The carried biotin could react with streptavidin and a biotin-labeled initiator strand (S0) in sequence. Two auxiliary DNA strands (S1 and S2) were designed for the concatamer reaction with the S0. The DNA initiator stand (S0) could propagate a chain reaction of hybridization events between alternating S1 and S2 to form a nicked double-helix. Upon addition of hemin, the hemin-binding aptamers can be bound to form the hemin/G-quadruplex-based DNAzymes on the S1 probe. Meanwhile, the formed double-helix DNA polymers could also cause the numerous intercalation of electroactive methylene blue. During the electrochemical measurements, the DNAzymes could catalyze the reduction of H2O2 in a detection solution with the aid of the intercalated methylene blue. Under the optimal conditions, the electrochemical immunosensor exhibited a dynamic working range of 1.0 pg mL−1–50 ng mL−1 toward CEA standards with a detection limit of 0.5 pg mL−1. The reproducibility and selectivity of the developed immunoassay were acceptable (CV <10%). In addition, 6 spiked CEA samples with various concentrations were assayed by using the developed immunoassay, and the recovery was 92–120%.Keywords
This publication has 33 references indexed in Scilit:
- Detection of exosomal biomarker by electric field-induced release and measurement (EFIRM)Biosensors and Bioelectronics, 2013
- Electrochemical immunosensor with N-doped graphene-modified electrode for label-free detection of the breast cancer biomarker CA 15-3Biosensors and Bioelectronics, 2013
- A rapid and highly sensitive portable chemiluminescent immunosensor of carcinoembryonic antigen based on immunomagnetic separation in human serumAnalytica Chimica Acta, 2013
- Relative Quantitation of Glycoisoforms of Intact Apolipoprotein C3 in Human Plasma by Liquid Chromatography–High-Resolution Mass SpectrometryAnalytical Chemistry, 2013
- Immunosensors for Estradiol and Ethinylestradiol Based on New Synthetic Estrogen Derivatives: Application to Wastewater AnalysisAnalytical Chemistry, 2013
- Anodic‐Stripping Voltammetric Immunoassay for Ultrasensitive Detection of Low‐Abundance Proteins Using Quantum Dot Aggregated Hollow MicrospheresChemistry – A European Journal, 2013
- Development of a Potential High-Throughput Workflow to Characterize Sites of Bioconjugation by Immuno-Affinity Capture Coupled to MALDI-TOF Mass SpectrometryBioconjugate Chemistry, 2012
- A novel DNAzyme-based colorimetric assay for the detection of hOGG1 activity with lambda exonuclease cleavageAnalytical Methods, 2012
- Mass-Linked Immuno-Selective Assays in Targeted ProteomicsAnalytical Chemistry, 2012
- Thionine/nanogold multilayer film for electrochemical immunoassay of alpha-fetoprotein in human serum using biofunctional double-codified gold nanoparticlesAnalytical Methods, 2010