Simple and Efficient: Validation of a Cotton Wick Electrode for Animal Electroretinography
Authors:
- Carl ArndtCACarl Arndt
- Danièle BassetDBDanièle Basset
- Christian P. HamelCHChristian P. Hamel
- Philippe BrabetPBPhilippe Brabet
- Marie O. PequignotMPMarie O. Pequignot
- 4 November 2010
- journal article
- research article
- Published by S. Karger AG in Ophthalmic Research
- Vol. 45 (4) , 174-179
Abstract
Purpose: Electroretinography (ERG) is a widely used technique to test retinal function in humans and animals. Recordings are particularly dependent on the type of electrodes used, with the best electrodes often being expensive and not always easy to use. The need of a simple and effective electrode type has led us to search the efficacy of different types of electrodes used in practice and compare them with the modified cotton wick electrode. Material and Methods: A modified type of electrode made of a cotton wick and impregnated with NaCl is described, and the ERG results were compared with other types of electrodes. Results: Compared with standard metal wire loop electrodes, the cotton wick electrode results in obtaining higher amplitudes, a better inter-eye correlation in the same animal and a better reproducibility of the recordings over time. Conclusion: This cotton electrode is simple to make and easy to place. It provides reliable recordings during the entire life span of the animal and reliable comparisons between contralateral eyes, thus providing a powerful tool for ERG studies.Keywords
This publication has 17 references indexed in Scilit:
- Evaluation of 9-cis-Retinyl Acetate Therapy inRpe65−/−MiceInvestigative Ophthalmology & Visual Science, 2009
- Opioid Receptor-Activation: Retina Protected from Ischemic InjuryInvestigative Ophthalmology & Visual Science, 2009
- GABA agonists fail to protect the retina from ischemia–reperfusion injuryExperimental Eye Research, 2009
- The Effects of Different Anesthetic Agents on Short Electroretinography Protocol in DogsJournal of Veterinary Medical Science, 2009
- Electroretinography of Wild-Type and Cry Mutant Mice Reveals Circadian Tuning of Photopic and Mesopic Retinal ResponsesJournal of Biological Rhythms, 2008
- Non-invasive gene transfer by iontophoresis for therapy of an inherited retinal degenerationExperimental Eye Research, 2008
- Delayed Dark Adaptation in 11-cis-Retinol Dehydrogenase-deficient MiceJournal of Biological Chemistry, 2005
- The effect of body temperature on the murine electroretinogramDocumenta Ophthalmologica, 2003
- Evaluation of different recording parameters to establish a standard for flash electroretinography in rodentsVision Research, 2001
- Screening for mouse retinal degenerationsDocumenta Ophthalmologica, 1989