Electrogenerated Chemiluminescence Peptide-Based Biosensor for the Determination of Prostate-Specific Antigen Based on Target-Induced Cleavage of Peptide
Authors:
- 17 January 2014
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 86 (3) , 1372-1379
Abstract
A novel electrogenerated chemiluminescence peptide-based biosensor (ECL-PB) for the determination of prostate-specific antigen (PSA) was developed on the basis of target-induced cleavage of a specific peptide within Nafion film incorporated with gold nanoparticles (AuNPs) and ECL emitting species. A specific peptide (CHSSKLQK) was used as a molecular recognition element; tris(2,2′-ripyridine) dichlororuthenium(II) (Ru(bpy)32+) was used as ECL emitting species, and ferrocene carboxylic acid (Fc) was employed as ECL quencher. The ECL-PB biosensor was fabricated by casting the mixture of Nafion and AuNPs onto the surface of glassy carbon electrode to form AuNPs/Nafion film, and then, Ru(bpy)32+ was electrostatically adsorbed into the AuNPs/Nafion film; finally, the peptide-tagged with ferrocene carboxylic acid (Fc-peptide) was self-assembled onto the surface of the AuNPs. When PSA was present, it specifically cleaved the Fc-peptide, leading the quencher to leave the electrode and resulting in the increase of the ECL intensity obtained from the resulted electrode in 0.1 M phosphate buffer saline (pH 7.4) containing tri-n-propylamine. The results showed that the increased ECL intensity was directly linear to the logarithm of the concentration of PSA in the range from 5.0 × 10–12 to 5.0 × 10–9 g/mL. An extremely low detection limit of 8 × 10–13 g/mL was achieved because of the signal amplification through AuNPs and the ECL background suppression through Fc as ECL quencher. This work demonstrates that the combination of the direct transduction of peptide cleavage events with the highly sensitive ECL method is a promising strategy for the design of enzymatic cleavage-based ECL biosensors with high sensitivity and selectivity.Keywords
This publication has 48 references indexed in Scilit:
- Gold Nanoparticle-Based Activatable Probe for Sensing Ultralow Levels of Prostate-Specific AntigenACS Nano, 2013
- Ultrasensitive electrochemiluminescent immunosensor based on dual signal amplification strategy of gold nanoparticles-dotted graphene composites and CdTe quantum dots coated silica nanoparticlesAnalytical and Bioanalytical Chemistry, 2013
- Cancer Biomarker Detection in Serum Samples Using Surface Plasmon Resonance and Quartz Crystal Microbalance Sensors with Nanoparticle Signal AmplificationAnalytical Chemistry, 2012
- Positive Potential Operation of a Cathodic Electrogenerated Chemiluminescence Immunosensor Based on Luminol and Graphene for Cancer Biomarker DetectionAnalytical Chemistry, 2011
- Microfluidic chip-based nanoelectrode array as miniaturized biochemical sensing platform for prostate-specific antigen detectionBiosensors and Bioelectronics, 2011
- Biosensor developments: application to prostate-specific antigen detectionTrends in Biotechnology, 2007
- Multiplexed protein measurement: technologies and applications of protein and antibody arraysNature Reviews Drug Discovery, 2006
- Electrochemical and chemiluminescent immunosensors for tumor markersBiosensors and Bioelectronics, 2005
- Prostate-specific antigenSeminars in Cancer Biology, 1999
- Effect of Inflammation and Benign Prostatic Hyperplasia on Elevated Serum Prostate Specific Antigen LevelsJournal of Urology, 1995