Background: Ensuring the safety of dental unit waterlines (DUWLs) has become a pivotal issue in dental care practices, focusing on the health implications for both patients and healthcare providers. The inherent structure and usage conditions of DUWLs contribute to the risk of biofilm formation and bacterial growth, highlighting the need for effective disinfection solutions.The quest for a disinfection method that is both safe for clinical use and effective against pathogens such as Staphylococcus aureus and Escherichia coli in DUWLs underscores the urgency of this research. Materials: Chlorine dioxide disinfectants at concentrations of 5, 20, and 80 mg/L were used to treat biofilms of S. aureus and E. coli cultured in DUWLs. The disinfection effectiveness was assessed through bacterial counts and culturing. Simultaneously, human skin fibroblast cells were treated with the disinfectant to observe changes in cell morphology and cytotoxicity. Additionally, the study included corrosion tests on various metals (carbon steel, brass, stainless steel, aluminum, etc.). Results: Experimental results showed that chlorine dioxide disinfectants at concentrations of 20 mg/L and 80 mg/L significantly reduced the bacterial count of S. aureus and E. coli, indicating effective disinfection. In terms of cytotoxicity, higher concentrations were more harmful to cellular safety, but even at 80 mg/L, the cytotoxicity of chlorine dioxide remained within controllable limits. Corrosion tests revealed that chlorine dioxide disinfectants had a certain corrosive effect on carbon steel and brass, and the degree of corrosion increased with the concentration of the disinfectant. Conclusion: After thorough research, we recommend using chlorine dioxide disinfectant at a concentration of 20 mg/L for significantly reducing bacterial biofilms in dental unit waterlines (DUWLs). This concentration also ensures satisfactory cell safety and metal corrosion resistance.Keywords
Funding Information
- Zhejiang Provincial Xinmiao Talents Program (2023R410033)
This publication has 29 references indexed in Scilit:
- Colonization by Pseudomonas aeruginosa of dental unit waterlines and its relationship with other bacteria: suggestions for microbiological monitoringJournal of Water and Health, 2019
- LIN28B/let-7 axis mediates pulmonary inflammatory response induced by diesel exhaust particle exposure in miceToxicology Letters, 2018
- Monitoring the decontamination efficacy of the novel Poseidon-S disinfectant system in dental unit water linesJournal of Microbiology, Immunology and Infection, 2017
- Substantivity of hypochlorous acid-based disinfectant against biofilm formation in the dental unit waterlinesJournal of Conservative Dentistry, 2017
- Efficacy of a Low Dose of Hydrogen Peroxide (Peroxy Ag+) for Continuous Treatment of Dental Unit Water Lines: Challenge Test with Legionella pneumophila Serogroup 1 in a Simulated Dental Unit WaterlineInternational Journal of Environmental Research and Public Health, 2016
- Changes in bacterial composition of biofilm in a metropolitan drinking water distribution systemJournal of Applied Microbiology, 2016
- Efficacy of dental unit waterlines disinfectants on a polymicrobial biofilmWater Research, 2016
- Correlation between antibiotic and biocide resistance in mesophilic and psychrotrophic Pseudomonas spp. isolated from slaughterhouse surfaces throughout meat chain productionFood Microbiology, 2015
- Pneumonia associated with a dental unit waterlineThe Lancet, 2012
- Biofilm problems in dental unit water systems and its practical controlJournal of Applied Microbiology, 2009