Abstract
Baseline wander is a common problem in analysis with Fourier Transform Infrared Spectrometer (FTIR). And it is necessary to correct baseline drift for further quantitative and qualitative analysis. Several baseline correction algorithms based on penalized least squares have been proposed. However, these methods are usually used in noise-free or low-noise environments. In this paper, a novel algorithm named adaptive smoothness parameter penalized least squares was proposed. The smoothness parameters were set by user at first. Then, the smoothness parameter was updated iteratively according to the difference between the original spectrum and fitted baseline. When the iteration reaches the termination condition, the fitted baseline can be obtained. In the end of the paper, experimental results on simulated spectra and measured infrared spectra of methane were given. The simulated spectra results demonstrate that the proposed method has better performance than existing methods, especially when the spectra contain high noise. The results of infrared spectra confirm that the proposed method has good performance and can be applied to correct spectral baseline accurately.Keywords
This publication has 22 references indexed in Scilit:
- Baseline correction method based on doubly reweighted penalized least squaresApplied Optics, 2019
- Baseline correction for Raman spectra using penalized spline smoothing based on vector transformationAnalytical Methods, 2018
- A fully automated algorithm of baseline correction based on wavelet feature points and segment interpolationOptics & Laser Technology, 2017
- Investigation of a genetic algorithm based cubic spline smoothing for baseline correction of Raman spectraChemometrics and Intelligent Laboratory Systems, 2016
- Multivariate qualitative analysis of banned additives in food safety using surface enhanced Raman scattering spectroscopySpectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2015
- The Piecewise Two Points Autolinear Correlated Correction Method for Fourier Transform Infrared Baseline WanderSpectroscopy Letters, 2014
- Automatic Baseline Recognition for the Correction of Large Sets of Spectra Using Continuous Wavelet Transform and Iterative FittingApplied Spectroscopy, 2014
- Comparison of Derivative Preprocessing and Automated Polynomial Baseline Correction Method for Classification and Quantification of Narcotics in Solid MixturesApplied Spectroscopy, 2006
- Investigation of Selected Baseline Removal Techniques as Candidates for Automated ImplementationApplied Spectroscopy, 2005
- FTIR-spectroscopy in microbial and material analysisInternational Biodeterioration & Biodegradation, 1998