An experimental glenoid rim strain analysis for an improved reverse anatomy shoulder implant fixation
Open Access
- 16 November 2011
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 30 (6) , 998-1003
Abstract
Loosening of glenoid components in TSA is a main cause of failure. In reverse anatomy TSA designs used for unstable joints, fixation is particularly demanding. Strains developed around the glenoid rim of biomechanical sawbone scapulae implanted with (a) the original fixed-fulcrum Bayley–Walker glenoid prosthesis in current clinical use, and (b) a revised version with conical cross-section, were compared. The conical shape of the revised design was hypothesized to produce greater strains in the glenoid rim than the original tapered screw design. The 2D strain field at three accessible locations around the rim of each scapula was measured with three-element rosette strain gauges for two types of simulated cancellous bone fill under applied physiologically relevant loads. The average strain energy densities around the rim for the conical design were greater than for the original design by a factor of 1.55–2.25 for all loading conditions. Results indicate that a significantly greater proportion of load was directed toward cortical bone in the conical design, thus promoting cortical bone loading. © 2011 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 30:998–1003, 2012Keywords
This publication has 21 references indexed in Scilit:
- Bone remodelling algorithms incorporating both strain and microdamage stimuliJournal of Biomechanics, 2007
- Influence of glenohumeral mismatch on bone strains and implant displacements in implanted glenoïds. An in vitro experimental study on cadaveric scapulaeJournal of Biomechanics, 2006
- Analysis of glenoid fixation for a reversed anatomy fixed-fulcrum shoulder replacementJournal of Biomechanics, 2004
- Shoulder prostheses treating cuff tear arthropathy: A comparative biomechanical studyJournal of Orthopaedic Research, 2004
- In vitro biomechanical analysis of glenoı̈ds before and after implantation of prosthetic componentsJournal of Biomechanics, 2002
- Patterns of loosening of the glenoid componentThe Journal of Bone and Joint Surgery. British volume, 2002
- The Kessel Total Shoulder ArthroplastyClinical Orthopaedics and Related Research, 1999
- The Kessel Prosthesis in Total Shoulder ArthroplastyClinical Orthopaedics and Related Research, 1992
- Total shoulder arthroplasty versus hemiarthroplastyThe Journal of Arthroplasty, 1990
- Constrained Total Shoulder ArthroplastyClinical Orthopaedics and Related Research, 1983