Respiratory control minimizes diaphragmatic contraction and dry cough during pulsed-field ablation of atrial fibrillation
Open Access
- 28 December 2023
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (1)
Abstract
Pulsed-field ablation (PFA) is a promising new ablation modality to treat atrial fibrillation. However, PFA can cause varying degrees of diaphragmatic contraction and dry cough, especially under conscious sedation. This prospective study presents a method to minimize the impact of PFA on diaphragmatic contraction and dry cough during the procedure. Twenty-eight patients underwent PFA for pulmonary vein (PV) and superior vena cava isolation under conscious sedation. Each patient received two groups of ablations in each vein: the control group allowed PFA application during any phase of respiratory cycle, while the test group used respiratory control, delivering PFA energy only at the end of expiration. A rating score system was developed to assess diaphragmatic contraction and dry cough. A total of 1401 control ablations and 4317 test ablations were performed. The test group had significantly lower scores for diaphragmatic contraction (P < 0.01) and dry cough (P < 0.001) in all PVs compared to the control group. The average relative reductions in scores for all PVs were 33–47% for diaphragmatic contraction and 67–83% for dry cough. The percentage of ablations with scores ≧2 for diaphragmatic contraction decreased significantly from 18.5–28.0% in the control group to 0.4–2.6% in the test group (P < 0.001). For dry cough, the percentage decreased from 11.9–43.7% in the control group to 0.7–2.1% in the test group. Pulsed-field ablation application at the end of expiration can reduce the severity of diaphragmatic contraction and eliminate moderate and severe dry cough during PV isolation performed under conscious sedation.Keywords
Funding Information
- AccuPulse Medical Technology (Suzhou) Ltd
This publication has 34 references indexed in Scilit:
- Outcomes after cryoablation vs. radiofrequency in patients with paroxysmal atrial fibrillation: impact of pulmonary veins anatomyEP Europace, 2016
- Contact-force guided radiofrequency vs. second-generation balloon cryotherapy for pulmonary vein isolation in patients with paroxysmal atrial fibrillation--a prospective evaluationEP Europace, 2014
- In-Hospital Complications Associated With Catheter Ablation of Atrial Fibrillation in the United States Between 2000 and 2010Circulation, 2013
- Updated National Multicenter Registry on Procedural Safety of Catheter Ablation for Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2013
- Cryoballoon Ablation of Pulmonary Veins for Paroxysmal Atrial FibrillationJACC, 2013
- Procedural Complications, Rehospitalizations, and Repeat Procedures After Catheter Ablation for Atrial FibrillationJACC, 2012
- Complications arising from catheter ablation of atrial fibrillation: Temporal trends and predictorsHeart Rhythm, 2011
- High-frequency irreversible electroporation (H-FIRE) for non-thermal ablation without muscle contractionBioMedical Engineering OnLine, 2011
- Efficacy and safety of cryoballoon ablation for atrial fibrillation: A systematic review of published studiesHeart Rhythm, 2011
- Efficacy and Safety of Circumferential Pulmonary Vein Isolation Using a Novel Cryothermal Balloon Ablation SystemJACC, 2005