The determination of polybrominated diphenyl ether congeners by gas chromatography inductively coupled plasma mass spectrometry
Authors:
- 1 October 2008
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 23 (12) , 1575-1580
Abstract
Polybrominated diphenyl ethers (PBDE) are flame retardant chemicals used in everyday household items such as computer casings and household textiles. Leaching and migration of these chemicals from products has been reported as the cause for the widespread presence of these compounds in our environment. While PBDEs are predominantly analyzed by GC-NCI-MS, GC-HRMS or GC-ECD, this paper investigates the potential of GC-ICP-MS for the determination of PBDEs. The application of this methodology for the analysis of PBDEs in NIST SRM 2977 Mussel Tissue and NIST 1941b Marine Sediment is also presented. The extreme sensitivity of inductively coupled plasma mass spectrometry (ICP-MS) for atomic information makes GC-ICP-MS a promising alternative for analyzing PBDEs at low concentrations or in small sample sizes. In this work, the instrumental detection limits of a GC-NCI-MS were directly compared to those of a GC-ICP-MS for a mixture of 28 PBDE congeners including the decabrominated PBDE-209 congener. The GC-ICP-MS instrumental method demonstrated superior sensitivity over the GC-NCI-MS for all of the PBDE congeners with absolute detection limits ranging from 0.2 pg to 0.3 pg as compared to 1.5 pg to 24.3 pg for GC-NCI-MS. The GC-ICP-MS method was then used to quantify PBDE congeners in Standard Reference Material (SRM) 1941b Organics in Marine Sediment and SRM 2977 Freeze-Dried Mussel Tissue (Organic Contaminants and Trace Elements). The mass fraction of PBDE congeners in these SRMs determined by GC-ICP-MS were within 13% (8.5%) and 7% (2.5%) (mean difference (1 SD)) of previously determined values for SRMs 1941b and 2977, respectively. The PBDE 209 value in SRM 1941b determined by GC-ICP-MS compared favorably to the consensus value from a recent interlaboratory comparison using this material (28.7 ng g−1 ± 2.9 ng g−1versus 24.4 ng g−1 ± 14.1 ng g−1).Keywords
This publication has 21 references indexed in Scilit:
- Polybrominated Diphenyl Ethers: A Case Study for Using Biomonitoring Data to Address Risk Assessment QuestionsEnvironmental Health Perspectives, 2006
- Optimization of a microwave-assisted extraction large-volume injection and gas chromatography–ion trap mass spectrometry procedure for the determination of polybrominated diphenyl ethers, polybrominated biphenyls and polychlorinated naphthalenes in sedimentsAnalytica Chimica Acta, 2006
- Optimization of the determination of polybrominated diphenyl ethers in human serum using solid-phase extraction and gas chromatography-electron capture negative ionization mass spectrometryJournal of Chromatography B, 2005
- Measurement of Selected Polybrominated Diphenyl Ethers, Polybrominated and Polychlorinated Biphenyls, and Organochlorine Pesticides in Human Serum and Milk Using Comprehensive Two-Dimensional Gas Chromatography Isotope Dilution Time-of-Flight Mass SpectrometryAnalytical Chemistry, 2004
- Semiautomated High-Throughput Extraction and Cleanup Method for the Measurement of Polybrominated Diphenyl Ethers and Polybrominated and Polychlorinated Biphenyls in Breast MilkAnalytical Chemistry, 2004
- Retrospective Time-Trend Study of Polybrominated Diphenyl Ether and Polybrominated and Polychlorinated Biphenyl Levels in Human Serum from the United StatesEnvironmental Health Perspectives, 2004
- Development and application of a method for the analysis of brominated flame retardants by fast gas chromatography with inductively coupled plasma mass spectrometric detectionJournal of Analytical Atomic Spectrometry, 2002
- Optimization of congener‐specific analysis of 40 polybrominated diphenyl ethers by gas chromatography/mass spectrometryJournal of Mass Spectrometry, 2001
- Capillary gas chromatography for the determination of halogenated micro-contaminantsJournal of Chromatography A, 1999
- Reduction of electronic noise in inductively coupled plasma atomic emission and fluorescence spectrometric measurementsAnalytical Chemistry, 1983