Abstract
We propose highly sensitive bio-electronics glucose sensors. The design of the sensors is based on the field effect transistor (FET) operation. Three different design of FET based biosensors have been proposed and compared. The circular and rectangular side-gate FETs (electrolyte gated FETs) and the back-gate FET (bioelectronic FET). The source, drain and gate electrodes were deposited on the flexible PET substrate via shadow-mask by DC sputtering. The sensitive material which is used as the channel of the FETs is nickel-tungstate (NiWO 4 ) micro crystals synthesized by hydrothermal method. The measurement results show that the proposed back-gate FET biosensor has a superior performance compared to other designs. The resulting back gate bio-electronic FET biosensor shows a wide detection range (0-15 mM), a detection limit of 1 nM, a sensitivity of 650 μA.μM -1 , high reproducibility, good stability, and highly selectivity. There is high stability in sensor response during repeated bending cycles, with no perceptible change in FET performance observed after 100 cycles. The accurate response of the biosensor towards the real blood serum samples shows that the proposed NiWO 4 back gate FET biosensors has a great potential to work as novel bio-electronic glucose test strips.
Funding Information
  • Iran National Science Foundation (4013206)

This publication has 25 references indexed in Scilit: