Electrochemical impedance spectroscopic studies of titanium and its alloys in saline medium
Authors:
- 31 January 2007
- journal article
- research article
- Published by Wiley in Materials and Corrosion
- Vol. 58 (2) , 113-120
Abstract
The influence of potential on electrochemical behaviour of pure Ti, Ti‐6Al‐7Nb, and Ti‐6Al‐4V ELI alloy under saline conditions were investigated by electrochemical impedance spectroscopy (EIS). All measurements were carried out in saline solution (0.9% NaCl) at different impressed potentials (corrosion potential (Ecorr), 0 mV (SCE) and + 500 mV (SCE)) for 1 h. The experimental results were compared with those obtained by potentiodynamic polarization curves. The corrosion current densities obtained for the titanium alloys showed lower values than for pure Ti, indicating the formation of a stable passive film with time. Electrochemical impedance spectroscopic studies indicated that the resistance of the passive film increased with the impressed potential. The impedance spectra were fitted using a non‐linear least square (NLLS) fitting procedure. The magnitude of the corrosion resistance of titanium alloys under saline solution was compared and results are presented.Keywords
This publication has 22 references indexed in Scilit:
- Degradation characteristics of hydroxyapatite coatings on orthopaedic TiAlV in simulated physiological media investigated by electrochemical impedance spectroscopyBiomaterials, 2003
- Corrosion wear fracture of new β type biomedical titanium alloysMaterials Science and Engineering: A, 1999
- Discussion: Evaluation of Corrosive Degradation in Coated Steel Using Alternating Current Impedance SpectroscopyCorrosion, 1996
- Evaluation of Coating Degradation with Electrochemical Impedance Spectroscopy and Electrochemical Noise AnalysisJournal of the Electrochemical Society, 1994
- Joint replacement components made of hot-forged and surface-treated Ti-6Al-7Nb alloyBiomaterials, 1992
- Tissue-biomaterial interactionsJournal of Materials Science, 1987
- The electrochemical behavior of metallic implant materials as an indicator of their biocompatibilityJournal of Biomedical Materials Research, 1987
- A Nonlinear Least Squares Fit procedure for analysis of immittance data of electrochemical systemsSolid State Ionics, 1986
- Recording and Analysis of AC Impedance Data for Corrosion StudiesCorrosion, 1981
- In vitro corrosion testing of titanium surgical implant alloys: An approach to understanding titanium release from implantsJournal of Biomedical Materials Research, 1979