Ventilatory Failure, Ventilator Support, and Ventilator Weaning
Authors:
- 1 October 2012
- book chapter
- Published by Wiley
- Vol. 2 (4) , 2871-2921
Abstract
The development of acute ventilatory failure represents an inability of the respiratory control system to maintain a level of respiratory motor output to cope with the metabolic demands of the body. The level of respiratory motor output is also the main determinant of the degree of respiratory distress experienced by such patients. As ventilatory failure progresses and patient distress increases, mechanical ventilation is instituted to help the respiratory muscles cope with the heightened workload. While a patient is connected to a ventilator, a physician's ability to align the rhythm of the machine with the rhythm of the patient's respiratory centers becomes the primary determinant of the level of rest accorded to the respiratory muscles. Problems of alignment are manifested as failure to trigger, double triggering, an inflationary gas‐flow that fails to match inspiratory demands, and an inflation phase that persists after a patient's respiratory centers have switched to expiration. With recovery from disorders that precipitated the initial bout of acute ventilatory failure, attempts are made to discontinue the ventilator (weaning). About 20% of weaning attempts fail, ultimately, because the respiratory controller is unable to sustain ventilation and this failure is signaled by development of rapid shallow breathing. Substantial advances in the medical management of acute ventilatory failure that requires ventilator assistance are most likely to result from research yielding novel insights into the operation of the respiratory control system. © 2012 American Physiological Society.Compr Physiol2:2871‐2921, 2012.Keywords
This publication has 284 references indexed in Scilit:
- Peripheral chemoreceptors determine the respiratory sensitivity of central chemoreceptors to CO2The Journal of Physiology, 2010
- Oxidative stress is required for mechanical ventilation-induced protease activation in the diaphragmJournal of Applied Physiology, 2010
- Prolonged mechanical ventilation alters diaphragmatic structure and functionCritical Care Medicine, 2009
- Respiratory muscle fiber remodeling in chronic hyperinflation: dysfunction or adaptation?Journal of Applied Physiology, 2009
- The 2008 Carl Ludwig Lecture: retrotrapezoid nucleus, CO2 homeostasis, and breathing automaticityJournal of Applied Physiology, 2008
- Physiological properties of human diaphragm muscle fibres and the effect of chronic obstructive pulmonary diseaseThe Journal of Physiology, 2008
- The effect of lung volume on the co‐ordinated recruitment of scalene and sternomastoid muscles in humansThe Journal of Physiology, 2007
- Caspase-3 Regulation of Diaphragm Myonuclear Domain during Mechanical Ventilation–induced AtrophyAmerican Journal of Respiratory and Critical Care Medicine, 2007
- Electroencephalographic evidence for pre‐motor cortex activation during inspiratory loading in humansThe Journal of Physiology, 2007
- Analysis of lung volume restriction in patients with respiratory muscle weakness.Thorax, 1980