Accurate Mass as a Bioinformatic Parameter in Data-to-Knowledge Conversion: Fourier Transform Ion Cyclotron Resonance Mass Spectrometry for Peptide De Novo Sequencing
Author:
- 1 February 2007
- journal article
- Published by SAGE Publications in European Journal of Mass Spectrometry
- Vol. 13 (1) , 83-87
Abstract
With the availability of ultra-precise mass spectrometric biomolecular data, the accurate mass is becoming a physical quantity of high interest for bioinformatics tools and strategies. Fourier transform ion cyclotron resonance mass spectrometry with electrospray ionization or matrix-assisted laser desorption/ionization sources now allows the easy determination of amino acid composition of medium size, unknown peptides when employing combinatorial calculation of hypothetical parent and fragment ion masses. This new method, which in a second step, allows the reliable de-novo sequencing of completely unknown peptides [“composition-based sequencing (CBS)”1] appears to open a wide new field of bioanalytical investigation. It has been shown that even unspecifically cleaved proteins can be identified easily and reliably when accurate mass evaluation is combined with protein database search tools.2 It is quite clear that, while the nominal mass of a peptide has obviously no useful correlation to biomolecular structure, the accurate mass, instead, has a strong and direct correlation to structure that so far has not been exploited considerably by bioinformatic tools. It has already become obvious that accurate mass evaluation is going to become a central goal for bioinformatics strategies in the near future.3–11 Strategies for extracting structural, and even functional, information out of accurate mass values of biomolecules still have to be developed. Examples and prospects of accurate mass evaluation in bioinformatics for the field of proteomics are outlined in the following.Keywords
This publication has 21 references indexed in Scilit:
- Direct Protein Identification from Nonspecific Peptide Pools by High-Accuracy MS Data FilteringAngewandte Chemie International Edition, 2006
- De novo sequencing, peptide composition analysis, and composition-based sequencing: A new strategy employing accurate mass determination by fourier transform ion cyclotron resonance mass spectrometryJournal of the American Society for Mass Spectrometry, 2004
- Proteome analyses using accurate mass and elution time peptide tags with capillary LC time-of-flight mass spectrometryJournal of the American Society for Mass Spectrometry, 2003
- An accurate mass tag strategy for quantitative and high-throughput proteome measurementsProteomics, 2002
- The significance of monoisotopic and carbon-13 isobars for the identification of a 19-component dodecapeptide library by positive ion electrospray Fourier transform ion cyclotron resonance mass spectrometryRapid Communications in Mass Spectrometry, 2000
- Utility of Accurate Mass Tags for Proteome-Wide Protein IdentificationAnalytical Chemistry, 2000
- Exact mass measurements using a 7 tesla fourier transform ion cyclotron resonance mass spectrometer in a good laboratory practices-regulated environmentJournal of the American Society for Mass Spectrometry, 1999
- Automation of a Fourier transform ion cyclotron resonance mass spectrometer for acquisition, analysis, and e-mailing of high-resolution exact-mass electrospray ionization mass spectral dataJournal of the American Society for Mass Spectrometry, 1999
- Exact mass measurement in the absence of calibrant by Fourier transform mass spectrometryAnalytical Chemistry, 1983
- Exact mass measurement by Fourier transform mass spectrometryAnalytical Chemistry, 1980