Effective temporal resolution and image quality of volume scanning in 320-row detector CT
- 7 March 2019
- journal article
- research article
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 42 (2) , 503-510
Abstract
To measure the effective temporal resolution (eTR) and image quality for three reconstruction modes for non-helical volume scanning in area detector CT. Temporal sensitivity profiles (TSPs) were obtained and the full width of the TSP at half maximum was used as an index of the eTR. Image quality was assessed by image noise and the corrected artifact index. The half reconstruction mode had a higher eTR than the full and automatic patient motion collection (APMC) reconstructions. Compared to full reconstruction, the image noise with APMC and half reconstruction were increased by 16% and 35%. The corrected artifact index was lowest with APMC. The square root of full width at tenth maximum of the TSP showed a high coefficient of determination (R2 = 0.934) for image noise. This study revealed the TSPs and eTRs for non-helical volume scanning in area detector CT. A high eTR resulted in higher image noise.Keywords
This publication has 20 references indexed in Scilit:
- High pitch third generation dual-source CT: Coronary and cardiac visualization on routine chest CTJournal of Cardiovascular Computed Tomography, 2016
- Temporal resolution measurement of 128-slice dual source and 320-row area detector computed tomography scanners in helical acquisition mode using the impulse methodPhysica Medica, 2016
- Dual-source CT in blunt trauma patients: elimination of diaphragmatic motion using high-pitch spiral techniqueEmergency Radiology, 2015
- Comparison of Image Quality and Radiation Dose between High-Pitch Mode and Low-Pitch Mode Spiral Chest CT in Small Uncooperative Children: The Effect of Respiratory RateEuropean Radiology, 2015
- Is bronchial wall imaging affected by temporal resolution? comparative evaluation at 140 and 75 ms in 90 patientsEuropean Radiology, 2015
- Assessment of temporal resolution of multi-detector row computed tomography in helical acquisition mode using the impulse methodPhysica Medica, 2015
- Examination of the optimal temporal resolution required for computed tomography coronary angiographyRadiological Physics and Technology, 2013
- Lung Image Quality with 320-row Wide-volume CT Scans: The Effect of Prospective ECG-gating and Comparisons with 64-row Helical CT ScansAcademic Radiology, 2012
- Effects of Heart Rate on Motion Artifacts of the Aorta on Non-ECG-Assisted 0.5-Sec Thoracic MDCTAmerican Journal of Roentgenology, 2005
- High temporal resolution for multislice helical computed tomographyMedical Physics, 2000