A Fiber Optic Biosensor Based on Hydrogel-Immobilized Enzyme Complex for Continuous Determination of Cholesterol and Glucose
- 3 October 2018
- journal article
- research article
- Published by Springer Nature in Applied Biochemistry and Biotechnology
- Vol. 187 (4) , 1569-1580
Abstract
A multiparameter fiber optic biosensor for continuous determination of cholesterol and glucose was developed. This sensor was based on poly(N-isopropylacrylamide) (PNIPAAm)-immobilized glucose oxidase (GOx) complex (PIGC) and immobilized cholesterol oxidase (COD). The immobilized COD catalysis to the oxidation of cholesterol and PIGC catalysis to the oxidation of glucose could be performed at different temperatures. Therefore, the sensor could detect cholesterol and glucose continuously by changing temperature. The optimal detection conditions for glucose were achieved with pH 6.5, 30 °C, and 10 mg GOx (in 100-mg carrier), and those for cholesterol were achieved with pH 7.5, 33 °C, and 25 mg COD (in 250-mg carrier). The sensor has the cholesterol detection range of 20–250 mg/dL and the glucose detection range of 50–700 mg/dL. This biosensor has outstanding repeatability and selectivity, and the detection results of the practical samples are satisfactory.Keywords
Funding Information
- National Natural Science Foundation of China (Nos: 61575150, 61377092)
This publication has 39 references indexed in Scilit:
- Diffusion-controlled Mediated Electron Transfer-type Bioelectrocatalysis Using Microband Electrodes as Ultimate Amperometric Glucose SensorsAnalytical Sciences, 2017
- Nanosheets-assembled hierarchical microstructured Ni(OH)2 hollow spheres for highly sensitive enzyme-free glucose sensorsElectrochimica Acta, 2015
- Synthesis and characterization of nickel oxide hollow spheres–reduced graphene oxide–nafion composite and its biosensing for glucoseSensors and Actuators B: Chemical, 2015
- Rapid determination of cholesterol in milk containing emulsified foodsFood Chemistry, 2012
- Determination of cholesterol in food samples using dispersive liquid–liquid microextraction followed by HPLC–UVJournal of Chromatography B, 2009
- Simultaneous determination of serum mannose and glucose concentrations in dog serum using high performance liquid chromatographyResearch in Veterinary Science, 2008
- Method to determine enantiomeric excess of glucose by nonchiral high-performance liquid chromatography using circular dichroism detectionJournal of Chromatography A, 2008
- Macrophage NADPH oxidase activation, impaired cholesterol fluxes, and increased cholesterol biosynthesis in diabetic mice: A stimulatory role for d-glucoseAtherosclerosis, 2007
- Development of cholesterol biosensor based on immobilized cholesterol esterase and cholesterol oxidase on oxygen electrode for the determination of total cholesterol in food samplesBioelectrochemistry, 2007
- An Organic Phase Enzyme Electrode for CholesterolAnalytical Letters, 1991