Large area, one step synthesis of NiSe 2 films on cellulose paper for glucose monitoring in bio-mimicking samples for clinical diagnostics
- 7 June 2019
- journal article
- research article
- Published by IOP Publishing in Nanotechnology
- Vol. 30 (35) , 355502
Abstract
There is an urgent need to develop low cost electrochemical sensors wherein the sensor can be disposed after recording data, thereby eliminating the issue of inaccuracy arising from repeated sensing measurements, which plagues most conventional electrochemical sensors. This work is the first demonstration of a NiSe 2 based disposable, one time use electrochemical glucose sensor in bio-mimicking real samples wherein NiSe 2 was hydrothermally grown NiSe 2 on a biodegradable cellulose paper. Both physicochemical (x-ray diffraction, x-ray photoelectron spectroscopy, field emission scanning electron microscope) and electrochemical (impedance spectroscopy and cyclic voltammetry (CV)) characterization techniques confirmed the growth and presence of NiSe 2 on a cellulose paper. Electrochemical techniques like CV and amperometric (i–t) were utilized for the selective and sensitive oxidation of glucose. The results suggests that the proposed NiSe 2 sensor is effective in a linear range of 0.1–1 mM with fast response time (3.9 s), low detection limit (24.8 ± 0.1 μ M) and high sensitivity (0.25 A M −1 cm −2 ) at a potential applied ( E app = 0.55 V versus Ag∣AgCl). Prior to the real sample analyses i.e. glucose detection in human urine, the fabricated NiSe 2 sensor was tested for selectivity towards glucose in co-existing interferences (dopamine, ascorbic acid, uric acid, urea, sodium chloride, fructose, lactose and cysteine). Finally, glucose in artificial blood serum and urine samples was demonstrated with the fabricated NiSe 2 sensor and the results are comparable to the conventional laboratory methods. The present methodology presents a novel possibility towards the design of next generation, affordable point-of-care devices for a broad range of clinical diagnostics.Keywords
Funding Information
- Anusandhan National Research Foundation (PDF/2017/001447)
- Suzuki foundation fellowship
This publication has 27 references indexed in Scilit:
- MoS2 based ultra-low-cost, flexible, non-enzymatic and non-invasive electrochemical sensor for highly selective detection of Uric acid in human urine samplesSensors and Actuators B: Chemical, 2019
- Two-dimensional metal chalcogenides analogous NiSe2 nanosheets and its efficient electrocatalytic performance towards glucose sensingJournal of Colloid and Interface Science, 2017
- Fabrication of a solution-processed, highly flexible few layer MoS2(n)–CuO (p) piezotronic diode on a paper substrate for an active analog frequency modulator and enhanced broadband photodetectorJournal of Materials Chemistry C, 2017
- Graphene based biosensors for healthcareJournal of Materials Research, 2017
- Gold nanoparticles assembly on electrospun poly(vinyl alcohol)/poly(ethyleneimine)/glucose oxidase nanofibers for ultrasensitive electrochemical glucose biosensingSensors and Actuators B: Chemical, 2017
- Non-enzymatic glucose sensor based on Au nanoparticles decorated ternary Ni-Al layered double hydroxide/single-walled carbon nanotubes/graphene nanocompositeElectrochimica Acta, 2015
- A highly sensitive non-enzymatic glucose sensor based on bimetallic Cu–Ag superstructuresBiosensors and Bioelectronics, 2015
- Advances in paper-based point-of-care diagnosticsBiosensors and Bioelectronics, 2014
- Wearable Electrochemical Sensors and Biosensors: A ReviewElectroanalysis, 2012
- Nano nickel oxide modified non-enzymatic glucose sensors with enhanced sensitivity through an electrochemical process strategy at high potentialBiosensors and Bioelectronics, 2011