Abstract
Control forces in semi-active control systems are constrained by the dynamics of actuators that regulate energy transmission through variable damping and/or stiffness mechanisms. The potential benefit of the development and implementation of new semi-active control devices and applications can be determined by optimizing the controlled performance subject to the constraints of the dynamics of the system being controlled (given by the state equations), the constraints associated with the dynamics of the semi-active device, and the expected external forcing. Performance optimization of semi-active control systems is a constrained two-point boundary value problem. This paper shows how this constrained problem can be transformed into an unconstrained problem, and how to easily solve the related unconstrained problem with Matlab. The method is illustrated on the performance optimization of a simple semi-active tuned-mass-damper for a structure subjected to ground accelerations. Several possible extensions of this method and application are offered. Copyright © 2013 John Wiley & Sons, Ltd.Keywords
Funding Information
- National Science Foundation (NSF-CMMI-0900324)
This publication has 20 references indexed in Scilit:
- A fully dynamic magneto-rheological fluid damper modelSmart Materials and Structures, 2012
- Tracking control of variable stiffness hysteretic-systems using linear-parameter-varying gain-scheduled controllerSmart Structures and Systems, 2012
- A self-sensing magnetorheological damper with power generationSmart Materials and Structures, 2012
- Spectral analysis for a semi-active-passive net-zero base-shear design conceptEarthquake Engineering & Structural Dynamics, 2011
- Design and experimental characterization of an electromagnetic transducer for large-scale vibratory energy harvesting applicationsJournal of Intelligent Material Systems and Structures, 2011
- Shock isolation using an isolator with switchable stiffnessJournal of Sound and Vibration, 2011
- Mitigation of wind response of a tall building using semi‐active tuned mass dampersThe Structural Design of Tall and Special Buildings, 2010
- Adaptive passive, semiactive, smart tuned mass dampers: identification and control using empirical mode decomposition, hilbert transform, and short-term fourier transformStructural Control and Health Monitoring, 2009
- Semi-active control systems for seismic protection of structures: a state-of-the-art reviewEngineering Structures, 1999