Evaluation of treatment planning system of brachytherapy according to dose to the rectum delivered
Authors:
- 28 November 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 150 (3) , 312-315
Abstract
The aim of this study was to assess the actual dose delivered to the rectum and compare it with the treatment planning system (TPS) reports. In this study, the dose delivered to the rectum was measured by semiconductor diode detectors (PTW, Germany). The factors that influence diode response were investigated as well. Calibration factors of diodes were measured weekly to investigate the effect of time interval on the accuracy of calibration. Then 40 applications of patients with cervix carcinoma were evaluated. Rectum dose was measured by means of rectal dosemeter and compared with the TPS-calculated dose. In this research, the differences between the measured and the calculated dose were investigated. The mean difference between the TPS-calculated dose and the measured dose was 6.5 % (range: −22 to +39) for rectum. The TPS-calculated maximum dose was typically higher than the measured maximum dose. The study showed that the main reason for the difference was due to the movements of the patient and applicator shift in the elapsed time between the imaging and treatment stage. It is recommended that in vivo dosimetry should be performed in addition to treatment planning computation. In vivo dosimetry is a reliable solution to compare the planned and actual dose delivered to organs at risk.Keywords
This publication has 14 references indexed in Scilit:
- Dosimetric evaluation of rectum and bladder using image-based CT planning and orthogonal radiographs with ICRU 38 recommendations in intracavitary brachytherapyJournal of Medical Physics, 2008
- CT-guided intracavitary radiotherapy for cervical cancer: Comparison of conventional point A plan with clinical target volume-based three-dimensional plan using dose–volume parametersInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- In-vivo dosimetry for gynaecological brachytherapy: Physical and clinical considerationsRadiotherapy and Oncology, 2005
- A prospective study to assess the bladder distension effects on dosimetry in intracavitary brachytherapy of cervical cancer via computed tomography-assisted techniquesRadiotherapy and Oncology, 2005
- Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group☆ (I): concepts and terms in 3D image based 3D treatment planning in cervix cancer brachytherapy with emphasis on MRI assessment of GTV and CTVRadiotherapy and Oncology, 2005
- Comparison ofp-type commercial electron diodes forin vivodosimetryMedical Physics, 2003
- Rectal doses in intracavitary brachytherapy of gynecological malignancies: comparison of two dosimetric methodsRadiotherapy and Oncology, 2001
- Inter-observer variation in delineation of bladder and rectum contours for brachytherapy of cervical cancerRadiotherapy and Oncology, 2000
- In vivo dosimetry: Intercomparison between p‐type based and n‐type based diodes for the 16–25 MV energy rangeMedical Physics, 2000
- Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43Medical Physics, 1995