R-R Interval Estimation for Wearable Electrocardiogram Based on Single Complex Wavelet Filtering and Morphology-Based Peak Selection
Open Access
- 2 April 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 60802-60827
Abstract
Recent innovations in wearable electrocardiogram (ECG) devices have enabled various personal healthcare applications based on heart rate variability (HRV). However, wearable ECGs rarely undergo visual inspection by medical experts, hence may contain noise and artifacts. Because apparent changes in the recorded ECGs caused by noise and artifacts may hamper the extraction of QRS complexes, an R-R interval (RRI) estimation algorithm tolerant to these measurement faults is required as the initial step toward HRV analysis using wearable ECGs. This paper proposes a semi-real-time RRI estimation for wearable ECGs utilizing a two-stage structure. In the preprocessing stage, we use a complex-valued wavelet that can adaptively fit to morphological variations of the QRS complex while retaining computing resources for extracting the QRS complex features. In the decision stage, we make use of complex-valued features and select appropriate QRS complexes in consideration of three features: peak magnitude, peak location, and peak morphology (phase). Initial evaluations show that the QRS complex detection performance of the proposed method achieved the F1 score of 0.952 ± 0.040 when targeting pseudo ECG data created from open data assuming wearable ECGs, and of 0.986 ± 0.018 when targeting actual ECG data recorded by using a shirt-type wearable ECG device during an exercise activity. Furthermore, the proposed method was able to suppress overlook or misdetection of QRS complexes, so the obtained RRIs are closer to the reference RRIs. The proposed method therefore contributes to achieving accurate HRV analysis using wearable ECGs in terms of obtaining accurate RRIs.Keywords
This publication has 34 references indexed in Scilit:
- QRS Complex Detection Using Combination of Mexican-hat Wavelet and Complex Morlet WaveletJournal of Computers, 2013
- Conductive Polymer Combined Silk Fiber Bundle for Bioelectrical Signal RecordingPLOS ONE, 2012
- A systematic analysis of performance measures for classification tasksInformation Processing & Management, 2009
- Wavelet transforms and the ECG: a reviewPhysiological Measurement, 2005
- A Wavelet-Based ECG Delineator: Evaluation on Standard DatabasesIEEE Transactions on Biomedical Engineering, 2004
- LOW-OSCILLATION COMPLEX WAVELETSJournal of Sound and Vibration, 2002
- The impact of the MIT-BIH Arrhythmia DatabaseIEEE Engineering in Medicine and Biology Magazine, 2001
- PhysioBank, PhysioToolkit, and PhysioNetCirculation, 2000
- Heart rate variability: Standards of measurement, physiological interpretation, and clinical useEuropean Heart Journal, 1996
- The Electrocardiogram During ExerciseCirculation, 1966