Measured Winding Impedances of a Large A-C Motor
Authors:
- 1 March 1987
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. EC-2 (1) , 139-151
Abstract
This paper presents measured R, L, C, G parameters of the stator winding of a large A-C motor. The values of these parameters were determined within the frequency range from 100 Hz up to 10 MHz with a high quality impedance analyzer. Twenty different measurements of the R, L, C, G parameters of turns, coils and phases are reported. The results should be of help to utility engineers concerned with turn insulation breakdown and surge protection of large A-C motors. The presented data can be used as an aid in development and calibration of wave propagation models needed for computation of electromagnetic transients in the windings of rotating machines. Ontario Hydro's assistance in this work and EPRI's funding are gratefully acknowledged.Keywords
This publication has 3 references indexed in Scilit:
- Switching Surge Voltage Distribution in Superconducting GeneratorsIEEE Power Engineering Review, 1985
- Effect of Surge Wave Reflection Inside a Motor On Voltage Distribution Across Stator WindingsIEEE Transactions on Power Apparatus and Systems, 1985
- Surge Voltage Distribution in Line-End Coils of Induction MotorsIEEE Transactions on Power Apparatus and Systems, 1985