Development and validation of a fast and simple multi‐analyte procedure for quantification of 40 drugs relevant to emergency toxicology using GC‐MS and one‐point calibration
Authors:
- 24 September 2013
- journal article
- research article
- Published by Wiley in Drug Testing and Analysis
- Vol. 6 (5) , 472-481
Abstract
Diagnosis and prognosis of poisonings should be confirmed by comprehensive screening and reliable quantification of xenobiotics, for example by gas chromatography–mass spectrometry (GC‐MS) or liquid chromatography‐mass spectrometry (LC‐MS). The turnaround time should be short enough to have an impact on clinical decisions. In emergency toxicology, quantification using full‐scan acquisition is preferable because this allows screening and quantification of expected and unexpected drugs in one run. Therefore, a multi‐analyte full‐scan GC‐MS approach was developed and validated with liquid‐liquid extraction and one‐point calibration for quantification of 40 drugs relevant to emergency toxicology. Validation showed that 36 drugs could be determined quickly, accurately, and reliably in the range of upper therapeutic to toxic concentrations. Daily one‐point calibration with calibrators stored for up to four weeks reduced workload and turn‐around time to less than 1 h. In summary, the multi‐analyte approach with simple liquid‐liquid extraction, GC‐MS identification, and quantification over fast one‐point calibration could successfully be applied to proficiency tests and real case samples. Copyright © 2013 John Wiley & Sons, Ltd.Keywords
This publication has 35 references indexed in Scilit:
- Therapeutic and toxic blood concentrations of nearly 1,000 drugs and other xenobioticsCritical Care, 2012
- Development of an LC–MS/MS method for the quantitation of 55 compounds prescribed in combined cardiovascular therapyJournal of Chromatography B, 2011
- An automated screening method for drugs and toxic compounds in human serum and urine using liquid chromatography–tandem mass spectrometryJournal of Chromatography B, 2010
- Performance evaluation of three liquid chromatography mass spectrometry methods for broad spectrum drug screeningClinica Chimica Acta, 2010
- Automated Mass Spectral Deconvolution and Identification System for GC-MS Screening for Drugs, Poisons, and Metabolites in UrineClinical Chemistry, 2010
- Development of a broad toxicological screening technique for urine using ultra-performance liquid chromatography and time-of-flight mass spectrometryAnalytica Chimica Acta, 2009
- Do you really need that emergency drug screen?Clinical Toxicology, 2009
- Quantitative determination of forty-eight antidepressants and antipsychotics in human serum by HPLC tandem mass spectrometry: A multi-level, single-sample approachJournal of Chromatography B, 2006
- Developing an Analytical Toxicology ServiceToxicological Reviews, 2004
- Which Drug Tests in Medical Emergencies?Clinical Chemistry, 2003